SOI/ADL 2009-10
34/63
599 72 40-73
ExC7
STEAM_PUMP_TRIAC_AL
Steam Pump Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Steam Pump Disconnected (Wiring or Connector Failure, Diode
broken)
Steam Pump Failure
Steam Pump Triac Failure (Short Circuit, Diode Mode, Open
Circuit) (Satellite Board Failure)
ExC8
STEAM_PUMP_DIODE_AL
Steam Pump Diode Alarm
Disables steamer activation.
Steam Pump Diode Shortcutted or missing
ExC9
STEAM_PUMP_TRIAC_S_A
L
Steam Pump Sensing
Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Steam Pump Triac Sensing Circuit Failure (Satellite Board Failure)
ExCA
NO_STEAM_WATER_AL
Missing Steamer Water
Alarm
Disables steamer activation until cycle end. At end cycle signals
missing steam water.
No water into steam tank (level sensor disconnected or broken)
Water pipes clogged or broken
Steam pipes clogged or broken