MAIN_FAN_AUT_THERM
Main Fan Thermal cut-off
Alarm
Disables main fan and heater/compressor for a while, waiting for
possible thermal restoration.
If after 30 minutes (more or less) the situation does not return
normal sets 0x66 alarm
Main Fan Motor Failure
Main Fan Motor Triac Failure (Short Circuit, Diode Mode,
Open Circuit) (Satellite Board Failure)
Ex67
MAIN_FAN_TRIAC_S_AL
Main Fan sensing alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Main Fan Triac Sensing Circuit Failure (Satellite Board Failure)
Ex71
DRYING_NTC1_AL
Drying NTC Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
NTC1 reading out of Range
Wiring Failure
NTC Failure
NTC reading circuit Failure (Main Board Failure)
Ex72
DRYING_NTC2_AL
Steamer NTC Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
NTC2 reading out of Range
Wiring Failure
NTC Failure
Wrong NTC configuration
NTC reading circuit Failure (Main Board Failure)
Ex82
WRONG_RESET_POS_AL
Wrong Reset Position on
Selector
Stops cycle execution.
If detected on setup, does not allow cycle start.
The Main Board is powered also in RESET Position
Wiring Failure
Selector Failure (Main Board Failure)
Ex83
WRONG_SEL_READ_AL
Wrong Selector code
No Action
The position code of the selector is not recognized.
Wrong Selector Configuration (Main Board Failure)
Selector Failure (Main Board Failure)
Ex91
UI_MB_COM_AL
User Interface
Communication Alarm
Disables cycle execution until the communication is not restored.
If detected on setup, does not allow cycle start.
Wiring Failure
User Interface Board Failure
Main Board Failure
Ex92
UI_MB_PROT_INCONG_AL
User Interface Protocol
Incongruence Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
The User Interface mounted is not compatible with the Main Board
connected
Ex93
CFG_AL
MCF Checksum Alarm
The machine could not work until a right configuration file is
programmed
wrong Machine Configuration File
Ex94
CFG_CYC_AL
CCF Checksum Alarm
The machine could not work until a right configuration file is
programmed
wrong Cycle Configuration File
Ex97
SCFCTF_MISMATCH_AL
Missing Program on CTF
Alarm
Detected only on setup.
Does not allow cycle start.
wrong selector configuration (MCF) or missing cycle on cycle table
(CCF)
Ex9b
UI_EFL_COMM_AL
User Interface External
Flash
Communication Alarm
No Action
User Interface Board Failure
Ex9C
UI_CFG_CHKS_AL
User Interface
configuration checksum
alarm
No Action
Main Board - wrong MCF
Main Board - User Interface Communication problems
Ex9d
UI_RTC_AL_CODE_AL
Real Time Clock alarm
No Action
User Interface Board Failure