Behaviour
If steamer tank switch is on void position, the related icon
blinks on LCD, but this not prevents the steamer to be
heated up.
Position 3
Steamer Pump +
Steamer Water/Steam
Pipes (Visual)
Purpose of test:
To test the steamer pump and steamer in general
(pipes, connections, etc.).
Activated components:
Steamer heater is switched on to maintain steamer
temperature between working limits (130º - 150º).
The steamer pump is activated with short impulses
(as configured) to allow correct steam generation.
Behaviour
The digits on LCD show NTC2 steamer
temperature.
Phase LEDs are switched ON.
Working conditions:
Door closed (Time out 10 min.)
Position 4
Counter clockwise
drum rotation
Purpose of test:
To test drum motor in counter-clockwise direction.
Activated components:
Motor triac and relay of direction (for assembly line
request, in this position will be switched on tank
pump also).
Behaviour
Phase LEDs are switched ON
Working conditions:
Door closed (Time out 10 min).
Position 5
Slow Clockwise drum
rotation (+ Reduced
Fan for ENV06 CRM 2
motors)
Purpose of test:
To test drum motor in clockwise direction
Activated components:
Drum Motor triac.
The motor performs a low-speed movement (for
assembly line request).
Main Fan motor is activated on inverse direction (to
test direction relay)
Behaviour
Phase LEDs are switched ON
Working conditions:
Door closed (Time out 10 min).
Position 6
Heater ½ power +
Clockwise drum
ro Full Fan
Purpose of test:
To test the ½ heating power element.
Activated components:
High heating element, Drum Motor and Main Fan on
direct direction to give ventilation (full speed).
Behaviour
The digits on LCD show NTC1 drying temperature.
Phase LEDs are switched ON.
Working conditions:
Door closed (Time out 10 min.)