SOI/ADL 2009-10
31/63
599 72 40-73
Ex57
FCV_CURRENT_TRIP_AL
FCV Current Trip Failure
Disables motor moving and shutdon FCV board for 2 mintues, then
FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
FCV Board - Motor Wiring
Motor Connector
FCV Board
Ex58
FCV_OVER_CURRENT_AL
FCV over current Failure
Disables motor moving and shutdon FCV board for 20 seconds,
then FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
FCV Board - Motor Wiring
Motor Connector
FCV Board
Ex59
FCV_NOT_FOLLOWING_AL
FCV not folowing Failure
Disables motor moving and shutdon FCV board for 20 seconds,
then FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
FCV Board - Motor Wiring
Motor Connector
FCV Board
Ex5B
FCV_UNDER_VOLTAGE
AL
FCV unser voltage Failure
Disables motor moving and shutdon FCV board for 20 seconds,
then FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
Main Board - FCV power supply wiring
FCV Board Failure
Ex5C
FCV_OVER_VOLTAGE_AL
FCV over voltage Failure
Disables motor moving and shutdon FCV board for 2 mintues, then
FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
FCV BOARD Failure
Ex5D
FCV_UNKNOWN_MSG_AL
FCV unknown message
Failure
No action
Ex5E
FCV_MB_COM_AL
Wrong FCV - Main Board
communication
Disables motor moving and shutdon FCV board for 20 seconds,
then FCV is switched on and drum moving enbaled.
If this problem conitues after 47 retrials of 20 s last 20
minutes retrial, the cycle is stopped and FCV boards switched off
definitively (until next machine reset)
Main Board - FCV communication wiring
Main Board - FCV power supply wiring
Motor Thermal Cutoff
Main Board or FCV Board Failure
Ex5F
FCV_FAULT_AL
FCV Failure
Disables motor moving and shutdon FCV board for 20 seconds,
then FCV is switched on and drum moving enbaled.
If this problem conitues after 5 retrials the cycle is stopped and
FCV boards switched off definitively (until next machine reset)
FCV BOARD Failure
Ex62
HEAT_RELAY_FAILURE /
COMP_RELAY_FAIL
Heaters Alarm
(or Compressor Alarm for
Heat Pump)
Stops cycle execution. If is an Heater Alarm (no Heat Pump) starts
automatically a safety "Cooling Alarm - 10 minutes".
If detected on setup, does not allow cycle start.
Heaters Disconnected (Wiring or Connector Failure, Manual
Thermostat Cut-off)
Heaters Failure
Heaters Relay Failure (Main Board Failure)
Ex63
HEAT_ELEM_AUT_TERM /
COMP_AUT_THERM,
Heaters Thermal cut-off
Alarm
(or Compressor Thermal
Alarm for Heat Pump)
Disables heater/compressor for a while, waiting for possible thermal
restoration.
If after 30 minutes (more or less) the situation does not return
normal sets 0x62 alarm
Ex64
HEAT_S_AL /
COMPRESSOR_S_AL
Heaters Sensing Alarm
(or Compressor Sensing
Alarm for Heat Pump)
Stops cycle execution.
If detected on setup, does not allow cycle start.
Heaters Sensing Circuit Failure (Main Board Failure)
Ex65
MAIN_FAN_TRIAC_AL
Main Fan Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Main Fan Motor Disconnected (Wiring or Connector Failure)