40
the Tamper switch on the Control
Panel is triggered while the system
is in Armed mode, the Control Panel
will sound an audible alarm and
report
Panel Tamper
via SMS
message to the first telephone
number.
While the system is in Alarm off
mode or Home mode, the siren
doesn
’t sound, but report will be
sent.
If the
Normal
is selected under
Tamper alarm function, when the
Tamper switch on the Control Panel
is triggered, the Control Panel will
sound an audible alarm and report
Panel Tamper
via SMS message to
the first telephone number.
Sensor Low Battery
Any time battery low on any
sensor is detected, the Control
Panel will report
Low battery
via
SMS
message
to
the
first
telephone number.
Sensor battery restoration is also
reported.
Sensor Sabotaged
If the Tamper switch on the PIR
Sensor, Door Contact, Remote
Keypad, Bell Box (BX-15), is
triggered while the system is in Arm
mode, the Control Panel will sound
an audible alarm and report
Burglar Alarm
&
Sensor Tamper
Open
via SMS message to the first
telephone number.
While if the system is in Alarm off
mode or Home mode, the siren
doesn
’t sound, but report will be
sent.
The Control Panel will report,
when the Tamper switch on the
sensor is restored.
Sensor out-of-order
If the Control Pane
l can’t receive
the signals transmitted from an
individual sensor over the preset
supervisory period, a Lost of signal
& sensor zone & name fault event
will be displayed on the screen
when you arm the system.
If the Control Panel can
’t receive
the signal, the system will send
report via SMS message to the first
telephone number.
Sensor
Restoration
is
also
reported.
Interference
C-FENCCE HOME will detect
interference only on the 868Mhz
band.
When the system is programmed
with Interference Detection On,
and when there is an interference
detected for 30 seconds, the
Control Panel will report
Interference
via SMS message to
the first telephone number.