When
Final Door Option
is set to
Off
,
the Control Panel enters
Alarm On
mode only when the Exit Delay time is
up.
The system can also be armed by
pressing the
“LOCK symbol” the
Remote controller (Only if the Remote
Controller Entry option is Enabled).
3.2.2. Stopping the Exit Delay
The Exit can be stopped by using Control
Panel / Remote Controller / Remote Keypad to
disarm the system.
Step 1.
Press key, and the screen will ask
you to enter User PIN code while the
system continoues to count down.
Step 2.
Enter the User PIN code followed by
OK
,
two
short
beeps
will
be
performed indicating that the system
is now returns to Alarm off mode.
3.2.3. Extend the Exit Delay
During the Exit Delay Period, the delay time
can be extended by pressing the
ARM
button
on the Remote Controller or Remote Keypad.
Each time the
ARM
button is pressed, the
delay time will start counting from the
beginning.
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
For the below options of
Home
Arming
, they are specially designed
to provide more flexibility to partially
Armed the system.
Depending on the assigned Device
Attribute, the system will operates
differntly according to its natural of
Attribute.
3.3. Home Arm
The Home Arm Mode allows the home to be
Partial Armed, Thus, part of the System is
protected with the Alarm, yet, the other areas
allows the user to move freely without self
triggering the alarm.
<
<
N
N
O
O
T
T
E
E
>
>
For those devices that their Device
attribute is learnt as
Home Omit
,
Away Only
&
Away Entry&Day
Home Omit&Night Home Omit
will
NOT
trigger the Alarm when they are
activated.
3.3.1. Home Arming the System
Step 1.
Move the cursor to
Home Arm
position
and then press
OK
.
The defined EXIT Delay timer starts
to count down.
<
<
N
N
O
O
T
T
E
E
>
>
For the Exit Delay performance,
please refer to the NOTE on Exit
Delay Count Down Period under
Section 2. Away Arm Mode.
Step 2.
When the
Exit Delay timer expires
,
the Control Panel will perform 3 beeps
and the system is now in Home Arm
Mode.
<
<
N
N
O
O
T
T
E
E
>
>
The system can also be armed by
pressing the
HOME symbol
the
Remote controller.
3.4. Timer
o T i m e
D a t e
Y e a r
D a y l i g h t
3.4.1. Time
This is for you to program the current time to
be displayed. (Hour & minute)
T i m e S e t t i n g
0 0 : 0 0 (
O K )
Hour flashes first, use
&
keys to
choose a correct number for the current
hour. Hours are indicated by
00 ~ 23
.
Press
OK
to confirm. Next, the screen will
be displayed for you to set the correct