![Electia CTC-909B User Manual Download Page 43](http://html1.mh-extra.com/html/electia/ctc-909b/ctc-909b_user-manual_2378780043.webp)
38
PIR Sensor / IR Camera(CTC-
852)/Door Contact / Remote
Keypad / Bell Box (BX-15)
A
Tamper
switch
protects
the
enclosure from either being opened
or being removed from the mounting
surface.
Sensor Low battery
If the battery voltage of PIR sensor, IR
Camera(CTC-852),
Door
Contact,
Remote Keypad, Water Sensor, Remote
Controller, Bell Box (BX-15) or Smoke
Sensor is low, a Sensor Low Battery
message will be detected.
Sensor out-of-order
The Control Panel is able to receive the
supervisory signal from its devices to
indicate their proper functioning.
If the Control Panel does not receive
the signals transmitted from an
individual sensor within the pre-set
Supervision time, a
Sensor out of
order
fault event will be displayed on
the screen and the system will send
report to the Central Monitoring
Station immediately.
The PIR Sensor, Door Contact,
Water Sensor and Smoke Detector
will send supervised-signal to the
Panel at intervals between 30~50
min. The system will according to the
setting of the Supervision send report.
When the Control Panel cannot receive the
supervised signal from the device for preset
supervisory period, the yellow LED lights while
the fault message
“
Lost of signal & sensor
zone & name
” can be viewed on LCD.
Meanwhile, a sensor out-of
–order report is
sent to the Central Monitoring Station.
Interference
C-FENCCE
HOME
will
detect
interference only on the 868Mhz band.
After a continuous interference signal is
present for more than 30 seconds, an
interference
event
can
be
logged,
reported and displayed on the LCD (if
programmed so).
GSM-Related Failure
GSM Signal
If GSM module is not connected to
the GSM Base Station or if there is
any failure in the GSM Connection.
GSM Module Missed
If the GSM module is missing.
GSM PUK
When GSM Service is locked by the
GSM Base Station,
GSM PUK
will be
displayed to remind the user to ask
for the PUK Code from the Base
Station to unlock the service.
SIM Card
If the SIM card is missing or has not
been put in place.
3.13.1. Fault Message Display
When any fault situation persists, the
Control Panel will respond as below when
it is in Alarm off mode:
Yellow LED on
– Indicate that there
is fault situation in the current
Operating Area.
Yellow LED
display:
Area
Fault situation
light on
Fault exists
off
No fault
The LCD will display the type and
source of the fault in the
Fault
Display
section of the User Menu.
A warning beep will sound at every
30 seconds.
If a fault condition is detected while
the system is in full arm mode, the
fault event display will not be
generated
until
the
system
is
disarmed.
3.13.2. Clearing Fault Message Display
The Yellow LED will turn off automatically
once all of faulty conditions are restored, or
any faulty devices are removed. It can’t be
cleared manually.
On the contrary, the fault message display
retains even though the faulty conditions
have been restored.