37
A L A R M ! A L A R M !
A L A R M ! A L A R M !
When you come back and disarm the
system by pressing the
DISARM
button on
the Remote controller, the
Alarm warning
display still remains unchanged.
To clear the display, follow the same steps
as
Stopping the Alarm
described above,
you can see the source of the alarm.
If more than one alarm events including
Device
Tampered
have
occurred,
repeated pressing further keys, the alarm
events will be displayed one by one
sequentially until all events have been
displayed, then the screen returns to
Alarm off
.
3.12. False Alarm
Management
C-FENCCE HOME has 3 regulatory false
alarm management facilities built-in:
Dual-Ply Entry Warning
Alarm Abort Reporting
Sequential Verification Alarm
Reporting
3.12.1. Dual-Ply Entry Warning
This is to warn the user that an alarm
report to the Central Monitoring Station will
be made.
If a zone programmed as
Entry
or
Away
Entry,
with no correct PIN code entered
within the programmed Delay period, and
then a 30-sec internal alarm period is given
before an alarm report is made.
If a valid user PIN code is entered within
the 30-sec internal alarm period, the alarm
sounding will be stopped and the system
returns to normal status without sending
report.
If no valid user PIN code is entered, a
burglar alarm will be sent.
3.12.2. Mis Operation Reporting
Automatically, with latchkey reporting
(
Latch Rpt
) being set to
On
, all Arm /
Home / Disarm actions of the User PIN
code is reported to the Central Monitoring
Station every time.
3.12.3. Sequential Verification Reporting
A sequential verification alarm report is
generated when a second alarm from a
different Burglar DC or Burglar IR is
registered within a 30-min period.
This Sequential Verification Report will be
sent in addition to the zone alarm report.
Alarms cannot be verified after the Entry
Delay has been initiated.
3.13. Faulty Situations
The Control Panel is capable of detecting
following fault events:
Control Panel Low Battery
AC Power Fail
Sensor Out-of-order
Sensor Low Battery
Device and Control Panel
Tamper
Interference Detection (Only for
868MHZ Control Panel)
GSM-Related Failure
In case any fault condition is detected, the
Control Panel will respond with a
Fault
display and/or
Fault
alarm respectively
according to the nature of the faulty event.
Device Sabotaged
The Control panel, Door Contact,
Remote Keypad & PIR & IR Camera
(CTC-852) sensors are
Tamper
protected.
Control Panel
A Tamper switch protects C-FENCCE
HOME from any removal attempts
away from its cross mounting bracket
Another Tamper switch to protect the
Power Supply Lid from being opened
or removed.