EPIR2 User Manual v.1.4
External Power Supply & Backup Battery Status Notification Settings
Function
Command
Value Range / Comment
Example
Disable SMS/text
message regard-
ing the battery
replacement
XXXX_BATREPORT:
OFF
The system checks the backup
battery resistance every 10
days. If the backup battery is
disconnected or needs to be
replaced (if more than 2,5Ω
resistance is detected), the
system sends an SMS message
to User 1. You may wish to
configure the system to ignore
these changes.
1111_
BATREPORT:OFF
Enable SMS/text
message regard-
ing the battery
replacement
XXXX_BATREPORT:
ON
1111_
BATREPORT:ON
Temperature Notification Settings
Function
Command
Value Range / Comment
Example
Set temperature
MIN and MAX
values
XXXX_TEMP:
MIN:MAX
MIN = minimum temperature
boundary, [-10... 40] C; MAX =
maximum temperature bounda-
ry, [-10... 40] C.
1111_TEMP:-
10:30
System Control from Any Phone Number Settings
Function
Command
Value Range / Comment
Example
Unblock unknown
incoming num-
bers
XXXX_STR:ON
By default, the EPIR2 alarm sys-
tem can only be accessed from
each of up to ten mobile phones
that you program into it..
To allow access from any phone
number you need to enable
the current feature, which will
allow all password holders to
access the system.
1111_STR:ON
Block unknown
incoming num-
bers
XXXX_STR:OFF
1111_STR:OFF
NOTE:
The underscore symbol ‘_’ in these instructions represents a space. So when typing an
SMS/text message, replace the underscore symbol with a single space.