27
27
EPIR2 User Manual v.1.4
EKB3W idling resulting in return to sleep mode. Meanwhile:
a) if a zone or tamper, which is of the associated EKB3W keypad, is violated, EKB3W will in-
stantly wake up and initiate the Back-light Timeout. Meanwhile the keypad buzzer will emit
short beeps and the LED indicators will light ON indicating the violated zone or tamper num-
ber.
b) if a zone or tamper, which is not of the associated EKB3W keypad, is violated, EKB3W key-
pad will NOT wake up and will NOT initiate the Back-light Timeout as well as the buzzer will
NOT emit short beeps and the LED indicators will NOT light ON.
To configure Back-light Timeout and Test Time parameters, please refer to
ELDES Configuration
Tool
software.
NOTE:
Even when Back-light Timeout has expired, the character will be considered as typed in
once the appropriate EKB3W key is pressed, therefore we recommend using the [*] key to wake
up the keypad. However, if another character is typed in and you wish to cancel it, please press the
[*] key or wait for 10 seconds until the keypad buzzer will provide a long beep indicating that the
typed in characters have been cancelled.
NOTE:
To have exit and entry delay indication on the keypad, we highly recommend installing
EKB3W near the designated entrance/exit door and using EKB3W zone for wired magnetic door
contact connection.
2.3.2. How to configure and control the system by EKB3W
The system configuration and control by EKB3W keypad is carried out by entering a valid configu-
ration command using the number keys [0]... [9], [#] key for confirmation and [*] key to cancel the
characters that are being entered. Alternatively, the user can wait for 10 seconds until the keypad
buzzer will provide a long beep indicating that the entered characters have been cancelled. When
typing in the characters, the indication of each pressed key is provided by short beep of keypad
buzzer. Additionalty, the red indicators light up when the number keys [0]... [9] are being pressed.
Some commands require [BYPS], [CODE] and [STAY] keys as well. The structure of a standard con-
figuration command is a combination of digits. The variables are provided in lower-case letters,
while a valid parameter value range is provided in brackets.
2.3.3. How to arm the system by EKB3W
1.
To arm the system, enter any out of 10 available 4-digit user passwords using the number keys:
1
7
4
2
8
5
0
3
9
6
Enter user password:
uuuu
Value:
uuuu
– 4-digit user password
Example: 1111
2.
The system will initiate the exit delay countdown (by default – 15 seconds) intended for user
to leave the secured area. The countdown is indicated by short beeps provided by the mini-
buzzer built in to the keypad (if fitted).
3.
After the system is successfully armed, it will reply with confirmation by SMS message to
User 1
phone number (by default).