34
Elcom, spoločnosť s ručením obmedzeným, Prešov
Elcom, spoločnosť s ručením obmedzeným, Prešov
35
Uniq 150
Service manual
Service
manual
Uniq 150
2.14.3. Installation of VGA connctor holder into leg
Holder of extended connctors is set for Uniq Display 150. Serves to fit display connector into leg with
maintaining original features of Uniq Display 150, both in terms of protection IP.
1. Fix connector on VGA connector holder of Uniq Display 150. Screw are part of the connector.
2. Holder fix to leg with screws of connectors cover and also with screws of the longest leg strip, which are part of
original leg and remains from previous step. Lead connctor cable between holder and leg. Description of cables
interconnection is in individual chapter.
3. Set new leg strips into leg with screws remained from previous steps.
Figure 2.14.3. – Installation of VGA connctor holder into leg
Holder of
VGA connector
Cable la
yout
connector
and its screws
Leg strip
of ext. connectors
Screw M3 × 6 DIN965 conical
Screw M3 × 4 mm DIN7985A
Needed to order
Quantity
Ord. code
Leg strip 2.0 Devlyx/UniqPC
2
M051069
Holder of VGA connector
1
M051085
2.15. Installation and interconnection of COM ports
Com ports are connected to mainboard to COM connector. It is necessary to install extended connector
holder for Nx execution.
2.15.1. Com ports interconnection for Nx execution
1. Dismount D-SUB connector and solder it on cable.
2. Mount D-SUB connector.
3. Opposit end of cable put in self tapping connector.
Needed to order
Quantity
Ord. code
Cable flat RM1mm 40pin colored
0,45 m/1 port
M200155
Self tapping connector 40 pin RM = 2 mm
1
M190218
Connector D-SUB 9M on cable
1/1 port
M190011
* Max. 4 ports
Figure 2.15.1. – COM ports interconnection for Nx execution
D-SUB9M
40 pin 2 rows 2 mm
COM3
COM4
COM5
COM6
1
2
3
4
5
6
7
8
9
1
3
5
7
9, 10
2
4
6
8
11
13
15
17
19, 20
12
14
16
18
21
23
25
27
29, 30
22
24
26
28
31
33
35
37
39, 40
32
34
36
38
—
—
—
—
—
—
—
—
—
to conn. COM on MB
rear COM3-6 conn.
Rear view
1
5
6
9
Rear view
1
5
6
9
Rear view
1
5
6
9
Rear view
1
5
6
9
Top view, opened
Front view, closed
1
40
COM6
COM5
COM4
COM3
2.15.2. COM ports interconnection for Tx execution
1. Put flat cable(s) to self tapping connector.
2. Give 1,6 mm tubing on wires of cable with D-SUB connector, except the wire which connect two wires of flat cable,
use there 2,4 mm tubing.
3. Solder cable with D-SUB connector to flat cable according to figure.
Note: Process of step 2 and 3 repeat for each installed COM port.
4. Cover soldered places with tubing.
Needed to order
Quantity
Ord. code
Tubing 1,6 × 10 mm
50
M010003
Tubing 2,4 × 10 mm
4
M010004
Cable flat RM1mm 40pin colored
0,45 m/1 port
M200155
Summary of Contents for Uniq 150
Page 1: ...Uniq 150 Uniq 150 Service manual version 1 4 Elcom spolo nos s ru en m obmedzen m Pre ov...
Page 5: ...Elcom spolo nos s ru en m obmedzen m Pre ov 5 Service manual Uniq 150 1 General specification...