TROUBLESHOOTING
NP-DK50 2x4VR 110-AD-A-1_09-2020
54
09/2020
TROUBLESHOOTING
Risk of electric shock.
Before interfering with the equipment, first disconnect it from the mains (remove
the power socket).
Working with pressurised pneumatic components poses a risk of injury.
Before interfering with the equipment, vent the air tank and the compressed air
system to zero pressure.
Troubleshooting may only be performed by a qualified service technician.
Damage to the safety valve could cause pressure to rise to hazardous levels.
Never adjust a safety valve.
Malfunction
Possible cause
Solution
Compressor does
not switch on
No voltage in the pressure switch
Check voltage in socket
Check circuit breaker switch
–
switch to position switched-
on „I“
Loose conductor from terminal -
repair
Check electrical cord
– replace
defective cord
Motor winding failure, damaged
thermal protection
Replace motor or windings
Capacitor failure
Replace capacitor
Seized piston or other rotating part
Replace damaged components
Pressure switch does not switch
Check function of pressure switch
Compressor often
switches on
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Non-return valve (SV) leakage
Clean non-return valve, replace
seals, replace non-return valve
Large volume of condensed liquid in
pressure tank
Drain condensed liquid
Low compressor capacity
Check time of filling the air tank
Low pressure in
the air tank
(compressor
running constantly)
High air consumption of supplied
equipment
Decrease air consumption
Use compressor with higher
capacity
Leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Low capacity of the pump
Clean / replace the pump
Pump failure
Clean / replace the pump
Dryer failure
Replace dryer
Prolonged
operation of the
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connection
Summary of Contents for DK50 2x4VR/110/M
Page 1: ...DK50 2x4VR 110 User manual Benutzerhandbuch N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 4 INHALT 57 OBSAH 111...
Page 14: ...PRODUCT DESCRIPTION NP DK50 2x4VR 110 AD A 1_09 2020 14 09 2020 Fig 2 Adsorption dryer...
Page 15: ...PRODUCT DESCRIPTION 09 2020 15 NP DK50 2x4VR 110 AD A 1_09 2020 Fig 3 Cabinet...
Page 66: ...PRODUKTBESCHREIBUNG NP DK50 2x4VR 110 AD A 1_09 2020 66 09 2020 Abb 2 Adsorptionstrockner...
Page 67: ...PRODUKTBESCHREIBUNG 09 2020 67 NP DK50 2x4VR 110 AD A 1_09 2020 Abb 3 Geh use...
Page 120: ...POPIS V ROBKU NP DK50 2x4VR 110 AD A 1_09 2020 120 09 2020 Obr 2 Adsorp n su i...
Page 121: ...POPIS V ROBKU 09 2020 121 NP DK50 2x4VR 110 AD A 1_09 2020 Obr 3 Skrinka...
Page 166: ......
Page 167: ......