Description of operation 

A Jameson Aftercooler is a portable system consisting of an air-cooled trim cooler and a 

separator/filter. Wet warm air enters the trim cooler where it is cooled to a temperature 

approaching ambient. Water is condensed out during this cooling process. The saturated air 

and the liquid water proceed to the inlet of the separator/filter where the liquid water is 

removed. The process air out of the system is ready for use.  

 

SPECIFICATIONS 

2.1 INLET CONDITIONS

 

Refer to Table 1 below for the recommended operating conditions for the available 

Jameson Aftercooler models. 

 

JAC-245 

JAC-540 

Maximum Working Pressure (PSI) 

250 

250 

Maximum Working Temperature 

Aftercooler (°F)

 

250 

250 

Maximum Working Temperature 

Separator (°F)

 

150 

150 

Minimum Recommended 

Temperature (°F) 

35 

35 

Internal Airflow Rotary 

Compressor (Max CFM) 

245 

539 

Internal Airflow Piston 

Compressor (Max CFM) 

181 

432 

Max Air Pressure to Motor (PSI) 

60 

40 

Motor Air Consumption (CFM) 

17 

25 

Max Fan RPM 

3450 

1725 

 

 

Table 1: 

Inlet Conditions 

 

 