Description of operation
A Jameson Aftercooler is a portable system consisting of an air-cooled trim cooler and a
separator/filter. Wet warm air enters the trim cooler where it is cooled to a temperature
approaching ambient. Water is condensed out during this cooling process. The saturated air
and the liquid water proceed to the inlet of the separator/filter where the liquid water is
removed. The process air out of the system is ready for use.
SPECIFICATIONS
2.1 INLET CONDITIONS
Refer to Table 1 below for the recommended operating conditions for the available
Jameson Aftercooler models.
JAC-245
JAC-540
Maximum Working Pressure (PSI)
250
250
Maximum Working Temperature
Aftercooler (°F)
250
250
Maximum Working Temperature
Separator (°F)
150
150
Minimum Recommended
Temperature (°F)
35
35
Internal Airflow Rotary
Compressor (Max CFM)
245
539
Internal Airflow Piston
Compressor (Max CFM)
181
432
Max Air Pressure to Motor (PSI)
60
40
Motor Air Consumption (CFM)
17
25
Max Fan RPM
3450
1725
Table 1: