PRODUCT MAINTENANCE
09/2020
53
NP-DK50 2x4VR 110-AD-A-1_09-2020
compressed air circuit exceeds its pre-set value. The pressure relief valve closes as the pressure
drops.
The pressure in the compressed air circuit can only increase because of an
increase in flow resistance in the compressed air lines or as a result of a dryer
malfunction (e.g. solenoid valve malfunction), and therefore the repeated
opening of the relief valve requires a dryer function check and repairs if
necessary!
Consultation with the manufacturer is required before any adjustment is made to
the relief valve!
The outlet openings on the relief valve may not be blocked and the egress of
compressed air through them may not be restricted.
2 Dryer pressure valve
Fig. 33: Pressure relief valve
19. LONG-TERM SHUTDOWN
If the compressor is not going to be used for long period, it is recommended to drain all condensate
from the air tank and switch on the compressor for about 10 minutes, keeping the drain valve open
(1) (Fig. 14). Thereafter switch off the compressor using the switch (2) on the pressure switch (1)
(Fig. 20), close the drain valve and disconnect the device from the mains.
AD dryer shutdown
Vent pressure from the dryer chambers. (Fig. 25).
20. DISPOSAL OF DEVICE
Disconnect the equipment from the mains.
Release the air pressure in the pressure tank by opening the drain valve (Fig. 25).
Dispose of the equipment following all applicable regulations.
Entrust a specialised company to sort and dispose of waste.
Worn out components have no negative environmental impact.
Summary of Contents for DK50 2x4VR/110/M
Page 1: ...DK50 2x4VR 110 User manual Benutzerhandbuch N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 4 INHALT 57 OBSAH 111...
Page 14: ...PRODUCT DESCRIPTION NP DK50 2x4VR 110 AD A 1_09 2020 14 09 2020 Fig 2 Adsorption dryer...
Page 15: ...PRODUCT DESCRIPTION 09 2020 15 NP DK50 2x4VR 110 AD A 1_09 2020 Fig 3 Cabinet...
Page 66: ...PRODUKTBESCHREIBUNG NP DK50 2x4VR 110 AD A 1_09 2020 66 09 2020 Abb 2 Adsorptionstrockner...
Page 67: ...PRODUKTBESCHREIBUNG 09 2020 67 NP DK50 2x4VR 110 AD A 1_09 2020 Abb 3 Geh use...
Page 120: ...POPIS V ROBKU NP DK50 2x4VR 110 AD A 1_09 2020 120 09 2020 Obr 2 Adsorp n su i...
Page 121: ...POPIS V ROBKU 09 2020 121 NP DK50 2x4VR 110 AD A 1_09 2020 Obr 3 Skrinka...
Page 166: ......
Page 167: ......