PRODUCT MAINTENANCE
NP-DK50 2x4VR 110-AD-A-1_09-2020
44
09/2020
18.6. Check of safety valve
Turn the screw (2) on the safety valve (1) several
times to the left until the safety valve releases the
air.
Let the safety valve vent for a few seconds.
Turn the screw (2) fully to the right, the valve must
be closed now.
Fig. 22: Check of safety valve
Damage to the safety valve could cause pressure to rise to hazardous levels.
Never use the safety valve to release the air pressure in the air tank. This could
damage the safety valve. The valve is set to the maximum permitted pressure by
the manufacturer.
Never adjust a safety valve.
Venting compressed air poses an injury hazard.
Wear safety glasses when inspecting a safety valve.
18.7. Inlet filter replacement
Inlet filter replacement:
Remove the locking spring (3).
Pull out the rubber plug by hand (2).
Remove the dirty intake filter (1).
Insert a new filter and replace the rubber
plug.
Secure the plug with the locking spring
(3).
Pre-filter replacement:
Pull out the pre-filter by hand (4).
Replace with a new one and insert it
back.
Fig. 23: Inlet filter replacement
Summary of Contents for DK50 2x4VR/110/M
Page 1: ...DK50 2x4VR 110 User manual Benutzerhandbuch N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 4 INHALT 57 OBSAH 111...
Page 14: ...PRODUCT DESCRIPTION NP DK50 2x4VR 110 AD A 1_09 2020 14 09 2020 Fig 2 Adsorption dryer...
Page 15: ...PRODUCT DESCRIPTION 09 2020 15 NP DK50 2x4VR 110 AD A 1_09 2020 Fig 3 Cabinet...
Page 66: ...PRODUKTBESCHREIBUNG NP DK50 2x4VR 110 AD A 1_09 2020 66 09 2020 Abb 2 Adsorptionstrockner...
Page 67: ...PRODUKTBESCHREIBUNG 09 2020 67 NP DK50 2x4VR 110 AD A 1_09 2020 Abb 3 Geh use...
Page 120: ...POPIS V ROBKU NP DK50 2x4VR 110 AD A 1_09 2020 120 09 2020 Obr 2 Adsorp n su i...
Page 121: ...POPIS V ROBKU 09 2020 121 NP DK50 2x4VR 110 AD A 1_09 2020 Obr 3 Skrinka...
Page 166: ......
Page 167: ......