29
Chapter 3 System Settings
4.
Set Event Rules.
Item
Detail
Setting range
Name
Enter the name of the Event Rule.
Alphanumeric, kana
*1
, and
kanji
*1
(Up to 24 characters)
Status
Select whether to enable or disable the Event Rule.
Active / Inactive
Event
Select an event to trigger an action.
The items that can be set differ depending on the event.
Refer to the tables below.
Alert request received / Timer
expired / Video output status
change / Failover mode started
/ Auxiliary command
*2
/ System
Startup / Network Link Up
Action
Select the actions to be executed when an event
occurs. The items that can be set differ depending on
the action. Refer to the tables below.
Notification
/ Start a timer /
SNMP Trap / Failover Toggle
*1 This can be set only when displayed on the web browser.
*2 Used when live image screen auxiliary command execution is set as a trigger. Camera auxiliary
commands cannot be set as triggers.
Setting Range of “Event”
Event
Conditions/Situation
Alert request received
*3
Received HTTP alert command.
Timer expired
Timer set in “Action” has expired.
Video output status change
The HDMI connection status while power is on has changed.
Failover mode started
Switched to failover display.
Auxiliary command
Event executed with live screen auxiliary command.
System Startup
Main power is turned on.
Network Link Up
Network communication is enabled.
*3 Sending a alert display HTTP command from external device is required.For details, contact your dealer
or local EIZO representative.
Selecting “Alert request received” as an “Event”
Item
Detail
Setting range
Camera No.
Select the camera to receive the alert.
Any, from 1 to 48
Trigger Type
Select the timing of the event to occur.
Select “On” when setting display alert as a trigger, and
“Off” when setting hide alert as a trigger.
Any / On /
Off
ID
*4
Select the ID.
Any, from 1 to 16
*4 Can be set when the “Trigger Type” is “Any” or “On”.
Selecting “Timer expired” as an “Event”
Item
Detail
Setting range
Timer No.
Select the number of the timer.
1 to 8