- AB600A5015
Parameter List
- 55 -
12.3
Supplier level
(Code No. 3112)
Parameters Designation
Unit
Max
Min
Preset
Ind.
201
t2 Sewing foot switch-on delay after thread wiper with half
heelback
ms
2550
20
80
202
t3 Start delay after disabling the sewing foot lifting signal
ms
500
0
50
203
t4 Time of full power of sewing foot lifting
ms
600
0
500
205
t6 Thread wiper time
ms
2550
0
120
206
t7 Delay from end of thread wiper until sewing foot lifting On
ms
800
0
40
207
br1 Braking effect when varying the
preset value ≤ 4 stages (indicated
values only with transmission ratio 1:1)
55
1
15
208
br2
Braking effect when varying the preset value ≥ 5 stages (indicated
values only with transmission ratio 1:1)
55
1
20
209 dFw Thread wiper switch-on delay
ms
2550
0
0
211
tFL Sewing foot lifting switch-on delay with thread wiper off
ms
500
0
60
217
Sr Number of operating hours before service in steps of 10
(operating hours recording enabled if set at “0”).
Std
99900
***)
00000
00000
218
SkL Select custom machines
0 = No custom machine
1 = Model 204
2 = Big Bag
2
0
0
219
br3 Braking ramp for n < 350
when drive stopped
55
1
4
220 ALF Accelerating power of the drive (indicated values only with
transmission ratio 1:1)
55
1
35
221 dGn Speed gate 1
RPM
990
50
100
222
tGn Speed gate damping period
ms
990
0
20
225
br4 Setting the braking curve for the light barrier and machine run
blockage (values only with transmission ratio 1:1)
55
1
20
229 dP2 Delay of heelback (-2)
ms
2000
0
0
232 USS Overlock with fast scissors On/Off
1
0
0
234
pdo Restart after machine run blockage via pedal 0 position
1
0
1
B
236 FLP 0 = Fl always permitted
1 = FI only permitted in position 2
2 = FI after cutting stored pedal plus ½ lifts storing, pedal
minus 1 switches stored FI on.
3 = Storage for standing actuation FBxxx
4 = Fl generally deactivated
5 = Stored foot lifting at the seam end can be deactivated
with pedal plus ½ and pedal minus 1.
5
0
0
B
238 EnP Software debouncing for all inputs:
0 = No debouncing
1 = Debouncing
1
0
1
239 FEL Selection of the input function on socket B18/8
0 = Light barrier function, if 009 =1
All other functions as with parameter 240.
112
0
0
***)
The 4-digit value displayed must be multiplied by 10.