- AB600A5015
Parameter List
- 44 -
Mode 7 (overlock) parameter 232 = 1 (fast scissors) / parameter 018 = 0 (seam end with stop)
Mark
Function
Parameter Control
FAm
LS
UoS
-Pd
LSS
PLS
USS
Mode 7
Sewing foot lifting at the seam end
Light barrier
Sequence “overlock mode with stop”
Function “pedal in pos. –2” blocked
Start blockage with light barrier uncovered
Chain suction On after light barrier compensating
stitches
Funct
ion “fast scissors”
On
290 = 7
009 = 1
018 = 0
019 = 2
132 = 0
192 = 0
232 = 1
Key
-
n1
n2
n5
n7
Positioning speed
Maximum speed
Speed after light barrier sensing
Trimming speed
110
111
114
116
c3
c4
LS
kt1
kt2
kdF
Start
counting
for tape cutter 1
End counting for tape cutter 2
Light barrier compensating stitches
ON period of tape cutter 1 (M1)
ON period of tape cutter 2 (M2)
Switch-on delay of sewing foot lifting
002
003
004
281
283
288
≤n2*) When the light barrier compensating stitch count at speed n5 ends, the final count for the cutter (c4) is
controlled by the pedal.
If the stitch count for the cutter is set to 0 and the light barrier compensating stitch count is set to when
the cutting begins, the count is carried out at speed n5 independently of the pedal.