- AB600A5015
Instruction Manual
- 18 -
6.10 Control display of signal position and stop position
Function
Parameter
Display of position 1 and 2
(Sr3)
172
Control display
Segment
is turned on
corresponds to position 1 On
Segment
is turned off
corresponds to position 1 Off
Segment
is turned on
corresponds to position 2 On
Segment
is turned off
corresponds to position 2 Off
6.11 Positioning shift
Function
Parameters
Positioning shift
(PSv)
269
Determine by means of parameter
269
whether the drive is to stop exactly on the position (Parameter
269 =0
)
or some increments after the position.
6.12 Braking Characteristics
Function
Parameters
Braking ramp running
Braking ramp stop
Braking ramp for n < 350
when drive stopped
(br1)
(br2)
(br3)
207
208
219
Parameter
207
regulates the braking effect between speed stages
Parameter
208
influences the braking effect for the stop
Parameter
219
influences the braking effect before the stop
The following applies to all setting values: the higher the value, the stronger the braking reaction!
6.13 Braking Power at Standstill
Function
Parameters
Braking Power at Standstill
(brt)
153
This function prevents unintentional "wandering" of the needle at standstill.
The effect can be checked by turning the hand wheel.
The braking power is effective at standstill
- at stop in the seam
- after the seam end
The effect can be set
The higher the set value, the stronger the braking power