- AB600A5015
Parameter List
- 43 -
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 0 (seam end with stop)
Mark
Function
Parameter Control
FAm
LS
UoS
-Pd
tFS
LSS
PLS
USS
Mode
7
Sewing foot lifting at the seam end
Light barrier
Sequence “overlock mode with stop”
Function “pedal in pos. –2” blocked
Beginning of thread tension release at the start of
the seam
Start blockage with light barrier uncovered
Speed n5 after light barrier sensing
Tape cutter function
On
290 = 7
009 = 1
018 = 0
019 = 2
025 = 0
132 = 0
192 = 0
232 = 0
Key
-
n1
n2
n5
n7
Positioning
speed
Maximum speed
Speed after light barrier sensing
Trimming speed
110
111
114
116
c3
c4
LS
kt1
kdF
End
counting
for chain suction
Start counting for chain suction
Start counting for tape cutter
ON period of tape cutter
Switch-on delay of sewing foot lifting
002
003
004
281
288