6.9.1 Setting the reference position (Parameter 170)
The angular positions necessary on the machine e.g. “needle down position“ or “thread lever up position“ are
stored in the control. A reference position is needed in order to establish a relationship between position
transmitter information and actual mechanical position.
The reference position must be set:
For initial operation
After replacing the motor
Setting the reference position on the control
Input code number and select parameter
170
!
Press the
E
key
Display
Sr1
_
Press the
>>
key
Display
P o u
(character
“o” rotating) *
1
Turn hand wheel until rotating
character
o
goes off on the display.
Display
P o
By turning the hand wheel, set the
needle to the bottom dead center or
the needle point to the height of the
needle plate in the direction of rotation
of the motor shaft, while needle is
moving downward.
Configuration of the zero point of the machine
Press the
P
key once
Actual parameter number 170 is displayed *
2
or
Press the
P
key twice
Exit programming at the technician level.
6.9.2 Setting the positions
This is an explanation of terms for the following descriptions:
Position 1 means "Needle lower position"
Position 2 means "Thread lever up" or "Needle rod TDC"
Each position has a starting angle (start) and ending angle (end). The needle stop position always refers to the
starting angle.
Position parameters
Parameters
Start position 1
End position 1
Start position 2
End position 2
(P1E)
(P1A)
(P2E)
(P2A)
451
452
453
454
The position window 1 and position window 2 must not overlap. Consider that the width of the position window is
at least 30° (difference between start and end of the position)!
If positions are set via the Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR),
then only the starting angle must be set. The end angles are automatically set to 60° after the starting angle.
The needle positions should in principle only be set via the quick installation routine (SIR) to prevent erroneous
inputs. You are guided through the required parameters with it.
See Section
Fehler! Verweisquelle konnte nicht gefunden werden.
Setting and Putting into Service with the
Aid of the Fast Installation Routine (SIR)
It is only important to set the position window including end angle for specific cutting systems. For these
systems, the cutting duration is controlled via the end angle of the position.