- AB600A5015
Instruction Manual
- 30 -
7.15 Special pedal function Single stitch / Full stitch
Function
Parameters
Special pedal function Single stitch / Full stitch
Pedal travel forwards for detection of the special pedal function
Time for detection of the special pedal function
Speed for single stitch / full stitch
(EZP)
(GrP)
(dPd)
(n9)
041
042
051
122
With the single stitch / full stitch function, it is possible to enable the execution of a stitch though pedal forwards actuation.
For this it is necessary to move the pedal forward only far enough so that the percentage portion (e.g., 40%) of the maximum
possible pedal travel (100%) set by the parameter
042
, is not exceeded.
The execution is done as single stitch (Parameter
041 = 1
) or full stitch (Parameter
041 =2
)
If the travel set with parameter
042
is exceeded within the time set with parameter
051
, the drive runs with the speed
specified by the respective pedal setting, even when under the threshold.
First after pedal 0-position can the special pedal function be actuated again.
The single/full stitch is executed in the speed set with parameter
122
.
To ensure that only a single stitch is executed,
the setting 300 rpm
must not be exceeded.
041 =0
Special pedal function Off
041 =1
Single stitch:
The performs one rotation from position 1 to position 1. If it is standing in position 2, it runs to
position 1 the first time and then each time from position 1 to position 1.
041 =2
Full stitch:
The drive executes a complete rotation corresponding to its starting position.
7.16
Signal “Machine Running“
Function
Parameters
Mode "machine running"
Switch-off delay for signal "machine running"
(LSG)
(t05)
155
156
Set activation of signal “machine running” using parameters 155/156 .
155 =0
Signal "machine running" Off.
155 =1
Signal "machine running" will be issued whenever the drive is running.
155 =2
The signal "machine running" will be issued whenever the speed is higher than 3000 RPM
155 =3
Signal "machine running" will be issued whenever the pedal is not in position 0 or neutral.
155 =4
Signal "machine running" will be issued only after motor synchronization (one rotation at
positioning speed after power On).
156
Delay of switch-off time.
7.17 Signal Output Position 2
Logic level output
Signal whenever the needle is in the slot between position 2 and 2A
Independent of sewing, thus also when turning the handwheel manually
Suitable e. g. for the connection of a counter
An inverted signal is issued at socket B19/9
7.18 Signal Output 512 Impulses per Rotation (G1 or G2)
Logic level output
Signal whenever a generator slot of the position transmitter is sensed
512 impulses per rotation of the handwheel, if transmission 1:1 (F272 = 100)
Independent of sewing, thus also when turning the handwheel manually
Suitable e. g. for the connection of a counter
A signal (G1) is issued at socket B18+B19/1+6