- AB600A5015
Parameter List
- 58 -
Parameters Designation
Unit
Max
Min
Preset
Ind.
377
tFl Time monitoring foot lifting
sec
250
0
0
B
396
Target setpoint via input PedalC with frequency
0 = OFF
1 = ON / PedalD = Enable
2 = ON / input function 54 = Enable
2
0
0
401
EEP Immediate storage of all changed data
-
Input code number 3112 after power On
-
Press the E key
-
-Input parameter 401
-
Press the E key
-
Set display from 0 to 1
-
Press the E or P key
-
All data are stored
1
0
0
451
P1E
-
Start position
6.9.2
.Setting the Positions (Parameter 270 = 0 or 6)
359
0
452
P1A
-
End position 1 "Needle lowest position"
-
See Section
6.9.2
Setting the Positions (Parameter 270 = 0 or 6)
359
0
453
P2E
-
Start position 2 thread lever up" / "Needle rod OT"
-
See Section
6.9.2
.Setting the Positions (Parameter 270 = 0 or 6)
359
0
454
P2A
-
End position 2 thread lever up" / "Needle rod OT"
-
See Section
6.9.2
.Setting the Positions (Parameter 270 = 0 or 6)
359
0
467
MOT Selection of motor
1 = Efka DC1500 (512)
2 = Efka DC1550 (512)
3 = Efka DC1200 (512)
4 = Efka DC1250 (512)
5 = QE3760 (256) (Quick Rotan)
6 = QE5540 (256) (Quick Rotan)
7 = Reserved for machine manufacturers
8 = Reserved for machine manufacturers
9 = Efka DC1210
10 = Efka DC1230
11 = Reserved for machine manufacturers
12 = Reserved for machine manufacturers
13 = Reserved for machine manufacturers
14 = Efka DC1280
15 = Reserved for machine manufacturers
16 = Reserved for machine manufacturers
17 = Reserved for machine manufacturers
18 = Reserved for machine manufacturers
19 = Reserved for machine manufacturers
20 = Reserved for machine manufacturers
21 = Reserved for machine manufacturers
21
1
1
500
Sir Recall of Fast Ins
tallation Routine (SIR) (see chapter “Fast
Installation Routine (SIR)”
510
Transfer parameter settings from control to Memory Stick
511
Transfer parameter settings from Memory Stick to control
512
Compare control and Memory Stick parameter settings
513
Delete parameter setting file from Memory Stick
527
Transfer control software from Memory Stick to control
833
epd 0 = Function Off
1 = Pedal 2 release only from Pos. 1
902
APt Service routine to teach the analog pedal. Pedal forwards for standing operation
939
EnF Storage for threading function F-290 =66