- AB600A5015
Parameter List
- 57 -
Parameters Designation
Unit
Max
Min
Preset
Ind.
272
trr Transmission ratio between motor shaft and machine shaft
(calculation formula see instruction manual!)
The transmission ratio should be determined and indicated as
precisely as possible!
40000
150
1000
280
kd1 Delay time output M1
ms
5000
0
0
281
kt1 ON period output M1
ms
5000
0
100
282
kd2 Delay time output M4
ms
5000
0
100
283
kt2 ON period output M4
ms
5000
0
100
288
kdF Delay time until sewing foot On
ms
5000
0
380
290
FAm Selection of machine specific
mode
0 =
Lockstitch:
(FA1, FA2, FA3, FA1+FA2): e.g. BrotherDürkopp Adler,
Mitsubishi, Pfaff, Toyota
5 =
Chainstitch general:
M1, M2, M3 and M4 parallel sequence
6 =
Chainstitch
with
tape cutter
and
Fast scissors
and
M1 / M2
at the seam end
7 =
Overlook
8-46= No function
47
= Hand-stitch machine:
Guta
Activation necessary!
48-65= No function
66 =
Chainstitch:
Strobel VTD 410EV
67 =
Chainstitch:
Hengtai MP500
68 =
Lockstitch:
Typical/Mauser Klasse 333
69 =
Lockstitch:
Juki class 1760
70= Reserved
71= No function
72= CL205/CL204
»Slide-in strips for V810/820 =5/5«
73= Reserved
74=
Chainstitch:
Yamato VG
»Slide-in strips for V810/820 =5/5«
75= SHDA CL160-30
»Slide-in strips for V810/820 =5/5«
76= Reserved
77= Reserved
78=Golden Wheel CSR88914
»Slide-in strips for V810/820 =5/5«
79 Gute GT8700C
Other modes are selectable, however have the same functions as
mode 0.
76
0
5
328
ob Changing function keys on the control panel
0 = All keys are locked
1 = All keys are released, key
E
+ start backtack,
key + end backtack (except mode 7)
2 = All keys are released, button
E
affects chain suction,
impacts tape cutter (only in mode 7)
3 = Button E and no function
4 = 4 = Button E, + and
– no function
5 = Button E affects soft start, impacts tape cutter
and wiper
6 = Button E affects soft start, impacts tape cutter seat
start /end
6
0
1
340
1L Lower switching threshold of input IN1
%
100
0
30
341
1L Upper switching threshold of input IN1
%
100
0
80
360
11L Lower switching threshold of input LSM
%
100
0
50
361
11h Upper switching threshold of input LSM
%
100
0
70
362
15V
5V/+15V on B18
0 = +5V
1 = +15V
1
0
0
370
n2 Direct input of maximum speed
RPM
F-111
F-121
Display
374
nrd Reset speed
rpm
390
70
100
B