Object name
Command Parameter
range
Factory
setting
Data type
Units
Comments
Power limit
setting
!S855
50..120
80
decimal
Watts
Link power maximum
?S855
-
-
-
-
-
Normal speed
setting
!S856
50..100
80
decimal
%
Normal speed as a per-
centage of full speed
?S856
-
-
-
-
-
Standby
speed setting
!S857
55..100
70
decimal
%
Standby speed as a per-
centage of full speed
?S857
-
-
-
-
-
Temperature
readings
?V859
0..100
-
decimal
°C
Measured motor temper-
ature
0..100
decimal
°C
Measured motor control-
ler temperature
Link parame-
ter readings
?V860
0..500
-
decimal
0.1 Volts Measured link voltage
0..300
decimal
0.1 Amps Measured link current
0..15000
decimal
0.1 Watts Measured link power
Pump run
hours
?V862
0..65535
-
decimal
hours
Hours run by pump
Temperature
readings 2
?V865
-200..200
-
decimal
°C
Measured motor temper-
ature
-200..200
decimal
°C
Measured motor control-
ler temperature
-200..200
decimal
°C
Measured rotor tempera-
ture
Factory set-
tings
!S867
1
-
-
-
Reset all configuration
options and parameters
to the factory settings
PIC software
version
?S868
10
-
string
chars
Boot loader software ver-
sion number
(D396596XXX)
Speed control
!C869
0
-
decimal
-
Set target speed to full
speed
1
-
-
-
Set target speed to stand-
by speed
Timer options
!S870
0
1
decimal
-
Timer = disabled
?S870
1
-
-
-
Timer = enabled
Note that the timer is
permanently enabled on
ramp-up.
07/2021 - ©Edwards Limited