C
HAPTER
28
| Port Mirroring Commands
RSPAN Mirroring Commands
– 1027 –
4.
Use the
rspan remote vlan
command to specify the VLAN to be used for
an RSPAN session, to specify the switch’s role as a source, intermediate
relay, or destination of the mirrored traffic, and to configure the uplink
ports designated to carry this traffic.
RSPAN Limitations
The following limitations apply to the use of RSPAN on this switch:
◆
RSPAN Ports
– Only ports can be configured as an RSPAN source,
destination, or uplink; static and dynamic trunks are not allowed. A
port can only be configured as one type of RSPAN interface – source,
destination, or uplink. Also, note that the source port and destination
port cannot be configured on the same switch.
Only 802.1Q trunk or hybrid (i.e., general use) ports can be configured
as an RSPAN uplink or destination port – access ports are not allowed
(see
switchport mode
).
◆
Local/Remote Mirror
– The destination of a local mirror session (created
with the
port monitor
command) cannot be used as the destination for
RSPAN traffic.
Only one mirror session is allowed, including both local and remote
mirroring. If local mirroring is enabled, then no session can be
configured for RSPAN.
◆
Spanning Tree
– If the spanning tree is disabled, BPDUs will not be
flooded onto the RSPAN VLAN.
MAC address learning is not supported on RSPAN uplink ports when
RSPAN is enabled on the switch. Therefore, even if spanning tree is
enabled after RSPAN has been configured, MAC address learning will
still not be re-started on the RSPAN uplink ports.
◆
IEEE 802.1X
– RSPAN and 802.1X are mutually exclusive functions.
When 802.1X is enabled globally, RSPAN uplink ports cannot be
configured, even though RSPAN source and destination ports can still
be configured. When RSPAN uplink ports are enabled on the switch,
802.1X cannot be enabled globally.
RSPAN uplink ports cannot be configured to use IEEE 802.1X Port
Authentication, but RSPAN source ports and destination ports can be
configured to use it
◆
Port Security
– If port security is enabled on any port, that port cannot
be set as an RSPAN uplink port, even though it can still be configured
as an RSPAN source or destination port. Also, when a port is configured
as an RSPAN uplink port, port security cannot be enabled on that port.
Summary of Contents for ECS3510-10PD
Page 1: ...Management Guide www edge core com 10 Port Layer 2 Fast Ethernet Switch...
Page 2: ......
Page 4: ......
Page 48: ...CONTENTS 48...
Page 68: ...SECTION I Getting Started 68...
Page 78: ...CHAPTER 1 Introduction System Defaults 78...
Page 96: ...CHAPTER 2 Initial Switch Configuration Managing System Files 96...
Page 98: ...SECTION II Web Configuration 98...
Page 118: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 118...
Page 150: ...CHAPTER 4 Basic Management Tasks Resetting the System 150...
Page 196: ...CHAPTER 5 Interface Configuration VLAN Trunking 196 Figure 66 Configuring VLAN Trunking...
Page 238: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 238...
Page 264: ...CHAPTER 8 Spanning Tree Algorithm Configuring Interface Settings for MSTP 264...
Page 274: ...CHAPTER 9 Congestion Control Automatic Traffic Control 274...
Page 288: ...CHAPTER 10 Class of Service Layer 3 4 Priority Settings 288...
Page 304: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 304...
Page 424: ...CHAPTER 13 Security Measures DHCP Snooping 424...
Page 568: ...CHAPTER 14 Basic Administration Protocols OAM Configuration 568...
Page 596: ...CHAPTER 15 IP Configuration Setting the Switch s IP Address IP Version 6 596...
Page 614: ...CHAPTER 1 IP Services Configuring the PPPoE Intermediate Agent 614...
Page 784: ...CHAPTER 20 System Management Commands Powered Device 784...
Page 814: ...CHAPTER 22 Remote Monitoring Commands 814...
Page 1008: ...CHAPTER 26 Interface Commands Power Savings 1008...
Page 1022: ...CHAPTER 27 Link Aggregation Commands Trunk Status Display Commands 1022...
Page 1052: ...CHAPTER 29 Congestion Control Commands Automatic Traffic Control Commands 1052...
Page 1064: ...CHAPTER 31 UniDirectional Link Detection Commands 1064...
Page 1070: ...CHAPTER 32 Address Table Commands 1070...
Page 1130: ...CHAPTER 34 ERPS Commands 1130...
Page 1172: ...CHAPTER 35 VLAN Commands Configuring Voice VLANs 1172...
Page 1186: ...CHAPTER 36 Class of Service Commands Priority Commands Layer 3 and 4 1186...
Page 1302: ...CHAPTER 38 Multicast Filtering Commands MVR for IPv6 1302...
Page 1368: ...CHAPTER 40 CFM Commands Delay Measure Operations 1368...
Page 1390: ...CHAPTER 42 Domain Name Service Commands 1390...
Page 1448: ...CHAPTER 44 IP Interface Commands ND Snooping 1448...
Page 1450: ...SECTION IV Appendices 1450...
Page 1455: ...APPENDIX A Software Specifications Management Information Bases 1455 UDP MIB RFC 2013...
Page 1456: ...APPENDIX A Software Specifications Management Information Bases 1456...
Page 1482: ...COMMAND LIST 1482...
Page 1493: ......