WEATHERPROOF BOILER DIMENSIONS
WEATHERPROOF OIL BOILERS
SPACE HEATERS WITHOUT TANKLESS COIL
MODEL
RECOMMENDED
FIRING RATES
GPH
HEATING
CAPACITY
MBH
(1)
NET I=B=R
RATING
MBH
(2)
ANNUAL FUEL
UTILIZATION
EFFICIENCY %
(3)
STEADY STATE
EFFICIENCY %
NO.
SEC.
MULTI
PASS
COIL
“A” DIM.
LENGTH
PFO-4W
Min.
.60
71
61
82.9
88.23
4
Less
28⅛”
Max.
1.35
151
131
78.6
83.19
PFO-7W
Min.
1.05
124
107
82.9
88.24
7
Less
37⅞”
Max.
2.35
276
240
--
(4)
--
(4)
PFO-9W
Min.
1.35
159
138
82.5
88.26
9
Less
44⅜”
Max.
3.00
309
268
--
(4)
--
(4)
IMPORTANT: ANTIFREEZE ADDED TO WEATHERPROOF BOILERS MUST BE NON-TOXIC!!
(1) D.O.E. Heating capacity is indicated in thousands of Btu per hour. Use of antifreeze in any boiler can reduce capacity, net output and
efficiency by a significant amount.
(2) Net ratings are indicated in thousands of Btu per hour based on a piping and pickup allowance of 1.15.
(3) Annual Fuel Utilization Efficiency based on tests performed under U.S. Department of Energy standards and reported to the Federal
Trade Commission.
(4) Capacity greater than that requiring testing under F.T.C. regulations. Firing rates of 2.00 gph or less use a Beckett Model AFG oil
burner. Firing rates over 2.00 gph use a Beckett Model CF375 oil burner.
OUTDOOR BOILER RATINGS AND CAPACITIES
Figure #2
Summary of Contents for ULTIMATE PF Series
Page 2: ......
Page 16: ...16 BURNER WIRING RIELLO BURNER WIRING...
Page 17: ...17 MULTI ZONE SYSTEM WIRING AND PIPING...
Page 18: ...18 MULTI ZONE SYSTEM WIRING AND PIPING...
Page 19: ...19 PIPING WITH CIRCULATORS MULTI ZONE SYSTEM WIRING AND PIPING...
Page 20: ...20 MULTI ZONE SYSTEM WIRING AND PIPING...
Page 38: ...38 BOILER PARTS...
Page 44: ......