background image

.it

USER OPERATING INSTRUCTIONS

16,5 - 16,5 C

Summary of Contents for 16

Page 1: ... it USER OPERATING INSTRUCTIONS 16 5 16 5 C ...

Page 2: ......

Page 3: ...economy and a longer operational life The careful designing and risk analysis performed by our company have produced a safe product Nonethe less before performing any type of operation it is recommended to scrupulously comply with the instruc tions provided in this document and to always have it on hand Pay the utmost attention when handling ceramic parts where present Check that the floor where t...

Page 4: ...ity standards use only quality pellets rec ommended by the manufacturer The glass is equipped with a special air pass for self cleaning However it is not possible to avoid a light grey coating on the glass after a few hours of work This also depends on the type of pellet used Some pellets soil more than others 1 2 Liability With the delivery of this manual we decline any civil or penal liability f...

Page 5: ...s the key for 2 seconds the stove switches on or off 5 Decrease output The button allows you to decrease the output from a maximum of 5 to a minimum of 1 6 Increase output The button allows you to increase the output from a minimum of 1 to a maximum of 5 SET 2 1 Display indications 7 Chronothermostat LED Indicates that the weekly and or daily programming is active 8 Smoke discharge stove functioni...

Page 6: ...wer display 11 Remote control receiver 12 Menu setting LED 13 Temperature LED 14 Remote control reception LED 15 Pellet LED 1 2 3 7 8 9 10 11 15 14 13 12 4 5 6 Remote control 1 Increase temperature 2 Decrease temperature 3 Increase output 4 Decrease output 2 2 Description of remote control optional The remote control allows you to control the following functions 1 Increase temperature Pressing the...

Page 7: ... basket is positioned correctly All sections of the flue gas pipe must be able to be inspected If fixed it must have inspection openings for cleaning 2 4 Loading pellets into tank Pellets are loaded into the tank through the specific door at the back of the stove To load pellets act as follows Open the door at the top Pour the desired amount of pellets into the tank with due care pour enough pelle...

Page 8: ...5 Press the button to increase the value and the button to decrease it The display indicates the output value Change temperature The user can change the temperature at any time To change the temperature first press SET and then press or and select the desired value which will appear on the lower display After a few minutes the upper display will read ON 1 2 3 4 5 according to the output set while ...

Page 9: ...rameters Modifications after an improper access require the intervention of an au thorised technician NOT COVERED BY WARRANTY UT05 Indicates the time PROGRAM 1 starts The time can be changed at 10 minute intervals by acting on the keys and N B This parameter is only enabled if UT01 was previously set other than OFF UT06 Indicates the time PROGRAM 1 finishes The time can be changed at 10 minute int...

Page 10: ...08 9 00 UT 09 23 00 UT 10 Off1 Off2 0n3 Off4 On5 On6 Off 7 ATTENTION The temperature and output at which the stove operates during the time periods with programming ON will be those of the last extinction 5 0 Information on display OFF OFF the stove is off or in the extinction phase E g current time 14 30 UT08 Indicates the time PROGRAM 2 starts The time can be changed at 10 minute intervals by ac...

Page 11: ...e temperature at least 4 C higher than the one shown on the display If the display still reads ON T contact the Authorised Service Centre Pressing the key restarts the stove with the previously set parameters SERV ALARM When the text serv appears it means the stove has reached 900 working hours Contact the Authorised Service Centre for maintenance ALARM NO ACC failed ignition This is triggered whe...

Page 12: ...ce Centre Fig 3 manually rearmed thermostat 1 On off Switch 2 Power cable 3 Fuse F4AL250V 4 PC connection optional 5 Thermostat rearm button 6 Room temperature probe Medium mod 1 2 3 5 4 6 Large mod 1 2 4 3 5 6 5 6 3 4 1 2 EXTINCTION ALARM DURING WORK Triggered when the stove extinguishes during the work phase e g pellets in tank finished The display reads NO FIRE Press the key to reset the alarm ...

Page 13: ...t the bottom of the stove The two fans are completely independent one from another A gate valve regulates the air towards the front fan towards one rear duct or both rear ducts Two knobs at the top of the stove allow you to regu late the amount of air to be channelled towards the right or left rear duct ...

Page 14: ...s in order like before the intervention placing the brazier properly Please follow the following cleaning operations carefully Failure to per form them can cause problems to arise in stove operation Operating options 1st option 100 frontal heat 2nd option 60 frontal heat 40 right or left duct 3rd option 20 frontal heat 80 right or left duct The power of each of the 2 fans together with each of the...

Page 15: ...ot supplied with the stove This opera tion is especially necessary the first times the stove is lit espe cially if pellets other than those recommended by the manu facturer are used The frequency of this operation depends on how often the stove is used and on the choice of pellets The brazier support should also be checked cleaning any ash es with a vacuum cleaner 7 1 Cleaning the surfaces To clea...

Page 16: ...uld endanger stove operation Poor quality pellets can however dirty the glass ATTENTION Do not try to light the stove if the glass is broken 7 9 Cleaning the exhaust system Until you have acquired reasonable experience regarding operating conditions it is recommended to perform this maintenance operation at least every month Disconnect the power cable Remove the cap of the tee fitting and clean th...

Page 17: ...n changing the batteries not supplied remove the rear cover of the remote control making leverage with a small flat head screwdriver Fig 10 Replace the battery with a new N type 12V battery be ing careful not to swap the poles battery type and poles are however written on the plastic part of the remote control If the problem persists contact the Authorised Service Centre 9 0 Yearly maintenance by ...

Page 18: ...cing gaskets on pipes and flue gas extraction fan compartment Cleaning silicon tube connected to pressure switch Cleaning inspection and descaling of ignition resistance compartment replacement if necessary Cleaning control of synoptic panel Visual inspection of electric cables connections and power cable Cleaning pellet tank and checking screw gearmotor assembly backlash Replacing combustion door...

Page 19: ......

Page 20: ...o transcription or printing errors It reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova Italy tel 39 0376 57001 telefax 39 0376 660556 info unical ag com export unical ag com www unical eu www unical eu ...

Reviews: