TYPICAL VENT SAFETY SWITCH INSTALLATION
This boiler may also be installed with a pressure
switch. For side-wall vented boilers the unit uses a
.35” w.c. pressure switch. It is mounted to the jacket
T
T
OIL-FIRED
Pressure
Switch
Flexible
Tubing
Hose Barb
Connection
Connect the flexible tubing (provided)
from the hose barb on the burner mount-
ing plate to the positive (+) tap on the pres-
sure switch.
using the screws provided and is wired to the T-T
terminals on the Oil Primary for oil-fired boilers
(as
shown below)
.