BRINE TEMP. ALARM.
Allows the value to be set below which the alarm is activated due to low temperatures in the brine
circuit.
COOLING TEMP.ALARM.
Allows the value to be set below which the alarm is activated due to low outlet temperatures in
the production circuit.
MENU 2.2.5. Probe configuration
BRINE OUTLET TEMPERATURE.
Displays the type of temperature probe installed in the brine circuit outlet and its current
reading. It is also possible for a correction to be made to the probe reading.
BRINE INLET TEMPERATURE.
Displays the type of temperature probe installed in the brine circuit inlet and its current
reading. It is also possible for a correction to be made to the probe reading.
PRODUCTION OUTLET TEMPERATURE.
Displays the type of temperature probe installed in the heating circuit outlet and
its current reading. It is also possible for a correction to be made to the probe reading.
PRODUCTION INLET TEMPERATURE.
Displays the type of temperature probe installed in the heating circuit inlet and its
current reading. It is also possible for a correction to be made to the probe reading.
OUTSIDE TEMPERATURE.
Displays the type of outside temperature probe and its current reading. It is also possible for a
correction to be made to the probe reading.
MENU 2.3. Manual test
BRINE PUMP.
Allows the manual ENABLING / DISABLING of the brine pump's control relay (DO1) and for adjustments to
be made to the rotational speed percentage.
PRODUCTION PUMP/BUFFER PUMP.
Allows the relay to be manually ENABLED / DISABLED which controls the production
pump for HEATING / DHW / POOL production or the buffer storage tank pump (DO2) and adjustments to be made to the
rotation speed percentage.
AUXILIARY BRINE PUMP.
Allows relay to be manually ENABLED / DISABLED which controls an auxiliary brine pump in case
of heat pump is working by cogeneration mode (DO3).
AUXILIARY PUMP COOL TANK.
Allows relay to be manually ENABLED / DISABLED which controls an auxiliary pump cool
tank in cooling buffer tank mode (DO4).
FREE COOLING.
Allows the relay to be manually ENABLED / DISABLED which controls 3-way valves for free cooling (DO5).
ACTIVATION AUXILIARY SYSTEM.
Allows the relay to be manually ENABLED / DISABLED which controls auxiliary system
(DO6).
MENU 2.4. Alarm log
ALARM LOG.
Here it is possible to access the log of all the alarms that occurred during the period of operation of the heat
pump, indicating the date and time that they were activated.
INITIALISE ALARM LOG.
Allows the alarm history log of the supervisor to be cleared.
MENU 2.5. Default values
INITIALISE APPLICATION.
Allows the adjustments performed in menu 1 to be cleared. USER and 2. INSTALLER and restore the
factory default settings.
INITIALISE ENERGY METER.
Allows the history log of the heat pump's energy meters to be cleared.
MENU 2.6. Change password
NEW PASSWORD.
Allows the access password to menu 2 to be changed. INSTALLER (PW1).