![ECOFOREST ecoSMART Supervisor User, Installer And Technical Service Manual Download Page 17](http://html1.mh-extra.com/html/ecoforest/ecosmart-supervisor/ecosmart-supervisor_user-installer-and-technical-service-manual_2354348017.webp)
ecoSMART Supervisor user, installer and technical service manual
17
EN
Table 4.5.
Characteristics of the supervisor power supply.
Figure 4.10.
Connection scheme of the supervisor power supply.
NOTE
The power supply of elements controlled by DO digital outputs must be independent.
4.3.
Bus communication
For the supervisor to run properly, it is essential to keep pLAN bus communication with the cascade of heat pumps. Install a
shielded three-pole cable type AWG 20-22 between the pLAN terminals of the supervisor and the heat pumps.
P
E
G
N
D
R
/T
+
R
/T
-
pLAN
ecoGEO HP
P
E
G
N
D
R
/T
+
R
/T
-
pLAN
ecoGEO HP
P
E
G
N
D
R
/T
+
R
/T
-
pLAN
ecoGEO HP
P
E
G
N
D
R
/T
+
R
/T
-
pLAN
Supervisor
Figure 4.11.
Example pLAN bus communication cable connection for installations with cascade of heat pumps.
Some other Ecoforest devices also communicate with each other via their pLAN ports. In any case, all Ecoforest controllers that
connect via pLAN will establish a single pLAN network.
5.
Controller user menu guide
NOTE
The information included below corresponds to application versions launched after October 2019.
Other versions, both earlier and later, may differ slightly from the contents found in this section.
Depending on the settings configured by the technical service, there might be screens or screen
contents that are not shown.
If the following screen appears when accessing a menu, this means that the
service requested has not been enabled by the technical service.
DI7 DI8
DI5
DI4
DI3
DI2
DI1
AI12
AI11
AI10
AI9
DI6
AO5
AO4
AO3
AO2
AO1
AI8
AI7
AI6
AI5
AI4
AI2
AI1
AI3
Sgn
C
o
m
Sgn
24
V
a
c
Sgn
24
V
a
c
Sgn
24
V
a
c
Sgn
24
V
a
c
Vou
t
24
V
a
c
G
N
D
PE
G
N
D
Tx
/R
x+
Tx
/R
x-
Sgn
C
o
m
Sgn
C
o
m
Sgn
C
o
m
Vou
t
24
V
a
c
G
N
D
Vou
t
24
V
a
c
G
N
D
Vou
t
24
V
a
c
G
N
D
Vou
t
24
V
a
c
G
N
D
Sgn
Sgn
Sgn
Sgn
Sgn
Sgn
Sgn
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
Sgn
G
N
D
Sgn
G
N
D
Sgn
G
N
D
Sgn
G
N
D
Sgn
G
N
D
PE
G
N
D
Tx
/R
x+
Tx
/R
x-
PE
G
N
D
Tx
/R
x-
Tx
/R
x+
pLAN
BMS2
FBus
Fu
se
2
A
24 Vac
Control Power
Supply 230V
DO1
DO2
DO3
DO4
DO5
DO6
DO7
DO8
DO9
DO10
DO11
DO12
DO13
L1 L2/N PE
Fu
se
0
.5
A
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
Co
ntr
ol S
up
ply
230
V
ac
L1
L2
/N
Control Supply
230 Vac
L1
L2
/N
5h