ecoSMART Supervisor user, installer and technical service manual
31
EN
A screen will appear as shown in the figure. Press [←┘] to go to the next screen.
In “Trm1” change the control panel address again as shown in the figure.
Press [←┘] again and change the control panel privacy “Pr”. Press [←┘] until reaching
“No”, which is next to “Ok?” and change it to “Yes”. Press [←┘] to start control panel
address configuration.
If the control panel shows no image for more than 10 seconds when starting configuration, repeat the configuration step by step. If
this persists, check that the right software is loaded.
6.4.
pLAN communication cable connection
Connect the pLAN communication cable to the supervisor.
6.5.
Selecting the heat pump model
To select the heat pump model access the INSTALLER MENU (press [Prg]+[Esc] and enter the installer password PW1) ->
CONFIGURATION -> HEAT PUMP MODEL.
On the MODEL SELECTION screen select the model of heat pump you are using from the available options. You must select the
same model (HP1 or HP3) for all the heat pumps managed by supervisor.
6.6.
Service configuration
To configure all the services, configure it in each heat pump connected to supervisor the services (HEATING, COOLING, DHW and/or
POOL) that you want enabled. The heat pump where you enabled the service manage the sensor and/or the control signal. To
configure the heat pump see Installation and operating manual ecoGEO HP.
6.7.
Configuration of service response priorities
To configure the priorities for responding to the different services previously enabled, access in the supervisor to the INSTALLER
MENU (press [Prg]+[Esc] and enter the installer password PW1) -> CONFIGURATION -> SERVICES -> PRIORITIES.
On the PRIORITIES CONFIGURATION screen select the priorities for responding to the different services previously enabled from
among the options available in the heat pump.
6.8.
Configuration of the remote control
To configure the remote control options available to the supervisor access the INSTALLER MENU (press [Prg]+[Esc] and enter the
installer password PW1) -> REMOTE CONTROL.
On the REMOTE CONFIGURATION screen enable the desired remote control options available. Also select the type of logic to be
used for each of the options enabled between NO/NC (normally open / normally closed).