![Echelon LONWORKS PLT-22 User Manual Download Page 122](http://html1.mh-extra.com/html/echelon/lonworks-plt-22/lonworks-plt-22_user-manual_3897121122.webp)
PLT-22 Transceiver Programming
Item Check
When
Completed
Description
25
The correct standard transceiver type is defined for the
transceiver:
STDXCVR.TYP date of 1999 or newer for dual carrier
frequency operation
Power management disabled:
PL-20N for CENELEC access protocol disabled
PL-20C for CENELEC access protocol enabled
Power management enabled:
PL-20N-LOW for CENELEC access protocol disabled
PL-20C-LOW for CENELEC access protocol enabled
PLT-22 Transceiver Coupling Circuit General
Item Check
When
Completed
Description
26
A coupling circuit that is suitable for the intended
application is selected, and coupling circuit components meet
the specifications shown in chapter 4 (as appropriate).
27
The maximum value of C1 for Line-to-Earth coupling circuits
results in a maximum of 3.5mA ground leakage current (or
as required by local electrical codes and the presence of
GFIs/RCDs.)
28
Appropriate high voltage surge protection is provided and
has been verified. See chapter 4 surge protection section.
29
No filters, ferrite beads, or power supply transformers are in
the coupling circuit path.
30
Capacitors added for EMI suppression meet the
requirements of table 6.1.
B-4
Appendix B
Summary of Contents for LONWORKS PLT-22
Page 6: ...iv Echelon...
Page 14: ...1 8 Introduction...
Page 67: ...LONWORKS PLT 22 Transceiver s User Guide 5 7 Figure 5 3 Capacitor Input Power Supply Schematic...
Page 92: ...6 10 Design and Test for Electromagnetic Compatibility...
Page 110: ...7 18 Communication Performance Verification...
Page 114: ...8 4 References...
Page 118: ...A 4 Appendix A...