122
Eaton Power Xpert 9395 UPS Installation and Operation Manual 164201725—Rev 15
Oneline Drawing
UPS Model
Voltage
System Type
Input
Output
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS –Three UPM,
Common Rectifier Feed, Common Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Common Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Four UPM,
Common Rectifier Feed, Common Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Four UPM,
Common Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/450
9395-825/500
9395-825/550
400
480
400
480
Single Reverse Transfer UPS – Two UPM,
Common Rectifier Feed, Common Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/450
9395-825/500
9395-825/550
400
480
400
480
Single Reverse Transfer UPS – Two UPM,
Common Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/450
9395-825/500
9395-825/550
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Common Rectifier Feed, Common Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/450
9395-825/500
9395-825/550
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Common Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Common Rectifier Feed, Common Battery, IOM
Configuration
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Common Rectifier Feed, Separate Battery, IOM
Configuration
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Four UPM,
Common Rectifier Feed, Common Battery, IOM
Configuration
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Four UPM,
Common Rectifier Feed, Separate Battery, IOM
Configuration
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Three UPM,
Separate Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
9395-825/650
9395-825/750
9395-825/825
400
480
400
480
Single Reverse Transfer UPS – Four UPM,
Separate Rectifier Feed, Separate Battery, Dual-
Feed Configuration, Continuous Static Switch
Summary of Contents for Power Xpert 9395
Page 8: ......