NZM-XDMI-DPV1
(PROFIBUS-DPV1 Interface for
DMI)
168
11/04 MN01219002Z-EN
Octet 3
Bit 4 to Bit 7
Day, 10 position digit
–
Bit 0 to Bit 3
Day, 1 position digit
Octet 4
Bit 4 to Bit 7
Hour, 10 position digit
–
Bit 0 to Bit 3
Hour, 1 position digit
Octet 5
Bit 4 to Bit 7
Minute, 10 position digit
–
Bit 0 to Bit 3
Minute, 1 position digit
Octet 6
Bit 4 to Bit 7
Second, 10 position digit
–
Bit 0 to Bit 3
Second, 1 position digit
Octet 7
Bit 4 to Bit 7
Millisecond, 100 position digit
–
Bit 0 to Bit 3
Millisecond, 10 position digit
Octet 8
Bit 4 to Bit 7
Millisecond, 1 position digit
–
Bit 0 to Bit 3
Day of the week
Value 0 complies with not used
Value 1 corresponds to Sunday
Value 2 corresponds to Monday
Value 7 corresponds to Saturday
h
The clock in the DMI does not use milliseconds and
weekday internally. For this reason the respective data
fields are assigned with “0” when reading the object.
When writing the object, the values in the these data fields
are ignored.