40 |
P a g e
3) Press the
M+/MR
key again, the display will show
FLOAD
(full load).
Keep
100%
load (equal to full scale) and then press the
M+/MR
Key.
The display will show the corresponding AD count. Press the
M+/MR
Key
will show
C.DONE
(if not it will show C.FAIL)
and the indicator will power off
and then after restart, the display will return to the home screen showing the
actual weight.
5.3 Standard Calibration (SCAL)
After setting the range, capacity, division, decimal point and unit, we
have press the Tare Key then the display shows SCAL (Standard
Calibration). Then follow the following process.
1) The display shows
ZCAL
(zero calibration). We have to make sure
there is no weight in the platform and then press the
M+/MR
Key (enter).
Now the display will show AD counts.
4) Once again press the
M+/MR
Key. The display will show LOAD and we
have to place weight and then press the
M+/MR
Key (enter). Then the
display will show the 50% weight as per the full scale capacity, then enter
weight as per weight is placed on the scale. Then press the
M+/Mr
key(enter).then display will show the corresponding AD count. Pressing
the
M+/MR
Key will show C.DONE (if not, it will show C.FAIL)
and the
indicator will power off and then after restart, the display will return to the home
screen showing the actual weight.
6. Modes
6.1 Simple Weighing
User Should ensure the scale is showing the unit in kg, g or lb. and then
they can use the scale. User can simply keep the weight on the pan.