13 |
P a g e
Once the Peak hold is chosen as per requirement, press ‘ENTER’
button to select,and after selection the display will come to the
previous menu.
2.9 Auto Sleep Time (ASLP)
When ENTER key is pressed from “ASLP00”, the display will start
flashing ‘00’. Default value is 00.
We can set Auto sleep time from 00 to 99 minutes.
e.g. If we select 5, then if the scale display values is in zero for 5
minutes, the scale will go into sleep mode. During sleep mode, LCD
backlight will off and LED will show zero in dim.
2.10 Auto Tare (AtrE)
When ENTER key is pressed from “AtrE n”, the display will start
flashing ‘n’. Default value is n.
y –Auto Tare ON.
n- Auto Tare OFF.
When the scale is in zero condition and when we keep the weight, that
weight will be tared automatically after 3 seconds and when we place one
more weight, the display will show the actual weight.
When all the weights are removed, the display will show the tared value
in negative and the negative value will be cleared in 3 seconds.
When Auto Tare function is enabled, in the display Tare indication flashes
continuously in LED Variant, and in LCD Variant ‘A’ symbol flashing
continuously.