12 |
P a g e
2.7 Power On Zero (PZro)
When ENTER key is pressed from PZro y, the display will start flashing
‘y’. Default value is y.
y -Power On Zero function ON.
n- Power On Zero function OFF.
When POWER ON ZERO is ON, and when we power OFF and ON the
scale,the display will show Zero, irrespective of weight on the platform
which is < 20% of full scale.
If the weight on the platform is more than 20% of the full scale then
the display will show Err20.
If the display shows Err20, then the scale should be checked and
remove the extra weights placed on the platform and ensure the
platform is clear and then Power OFF and Power on the scale
(Note :Err 20 is not applicable for negative values)
2.8 Peak Hold (PHLd)
When ENTER key is pressed from “PHLd n”, the display will start
flashing ‘n’. Default value is n.
Once the peak value is held, when the user press Zero key, the peak hold
will be released.
n –Peak hold Function OFF.
y- Peak hold ON.
P- Progressive peak hold ON.