It is highly recommended that a set of safety infra-red beams be used in conjunction with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6.
Over and above the recommendation to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automatic closing feature. It is recommended that a warning light be fitted to any automation system.
7.
The emergency manual release instruction label must be installed on or adjacent to the emergency manual release mechanism.
After installation - It is the responsibility of the installer to ensure the users:
1.
Is proficient in the use of the manual emergency release mechanism.
2.
Is issued with the documentation accompanying this product.
3.
Understands that the gate or door may not be operated out of clear sight.
4.
Ensures that children are kept clear of the gate or door area at all times, and that children do not play with the remote transmitters
or any fixed trigger switches linked to the system.
5.
Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger of continuing to use the
automation system in an unsafe condition before a service provider attends to it.
6.
Is proficient in testing the unit’s safety obstruction sensing system.
7.
Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service
provider.
8.
Is aware that a fatigued battery may not be disposed of in the general refuse and must be handed in at a battery merchant for safe
disposal. Before removing the battery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the battery must be removed first.
Technical specifications.
Rated gate mass.
300kg
Maximum gate leaf length.
25m
Primary power supply to gate.
220 – 240Vac @ 50Hz – 60Hz
(A low voltage plug-in transformer can be purchased and installed if required)
Peak power consumption at gate
18W
Electrical class.
Class 1
Motor voltage.
24Vdc
Motor current limiting.
5A Starting / 3,5A Running
Rated duty cycle.
25% with 220Vac present (See determining your duty cycle on page 7)
Number of operations on battery reserve
within 24 hours of power failure.
100 (Gate load and battery health dependent. Based on a gate opening of 4m)
Gate speed.
25m/min (Gate load and battery health dependent)
Rated Load.
300N Starting / 240N Running
Operating temperature range.
-10 to 50° C (14F to 122F)
Anti-crushing safety sensing.
Yes – Electronic gate profiling
Auxiliary supply output.
12Vdc @ 400mA
Built in battery charger.
Multiple stage auto-calibrating (350mA peak)
Receiver format.
ET BLU MIX ® Backward compatible with ET BLUE (Rolling code)
Receiver frequency.
433.92MHz
Receiver channels.
4CH (BT, PED, Aux relay, Holiday lock-out)
Receiver memory capacity.
32 users
All users can be allowed control of all channels.
Yes
Ingress protection.
IPX4