19
Setting up the gate runtime. (Mandatory)
run
From Ready status
rdy
Before continuing with the runtime setup ensure the limit actuator has
been installed correctly as per page 16 in this manual. Begin with the
gate midway in its travel.
NB. To speed up the gate while running during this procedure, press and hold
either the < or > buttons.
Action
Response
Description
Display
Buzzer
Gate/s
To enter the program
menu. Press and hold the
button until buzzer
beeps.
Display and buzzer
confirms.
pr9
Scroll < or > to select the
runtime setup option.
Display scrolls
through options.
run
Ensure gate is engaged
midway and then press
button.
Display prompts
you to confirm gate
closing direction.
cl
dir
Confirm gate closing
direction by pressing and
releasing either the < or >
button.
Gate closes slowly.
Display confirms.
Lft
r9t
When the closed position
is reached and the closed
limit is triggered. LED on.
Gate stops and starts
opening.
lrn
Press and release the
button to stop the gate
at the required open
position.
Gate stops opening.
Display asks you to
fine adjust the open
position if required.
adj
Fine adjust the open
position using the < or >
buttons, if necessary.
Gate moves with
each button press in
either direction.
adj
When satisfied with the
open position, press and
release the
button to
save that position.
Gate closes slowly.
Display and buzzer
confirms.
lrn
When the closed position
is reached and the closed
limit is triggered. LED on.
Gate stops. Display
and buzzer warn the
profiling is about to
begin.
pro
Once warning tone has
stopped.
Gate begins running
open at full speed.
Display confirms.
pro
When the previously
programmed open
position is reached.
Gate stops and
begins closing again
at full speed. Display
confirms.
pro
When the closed position
is reached and the closed
limit is triggered. LED on.
Gate stops. Display
and buzzer confirms.
dne
x2
x1
STOP
x1
x1
On/off...
On/off...
x2
Scroll left or right to next
program option.
OR
rdy
EXIT back to ready