F 7.4 3
F_7
.4_
01_G
B.
fm
3-
6
1.2
Points of maintenance
Planetary gear (1)
- For checking the oil level unscrew
the inspection plug (A).
A
In case of proper oil level, the oil is at the
lower edge of the inspection port (A) or a
little oil flows from the hole.
For filling in the oil:
- Remove the inspection plug (A) and
filling plug (B).
- Fill oil of the correct specification
through the filling hole (B) until the oil
level reaches the lower edge of the in-
spection hole (A).
- Replace the inspection plug (A) and
filling plug (B).
Oil change:
A
Change the oil when the engine is at op-
erating temperature.
m
Make sure that no pollution or foreign
matter gets into the drive.
- Stop the machine so that the “TOP” is at the topmost position and the drain plug
(C) is at the bottom.
- Unscrew the drain plug (C) and the filling plug (B) and drain the oil.
- Check and replace the seals of both screw plugs.
- Return drain plug (C).
- Remove the inspection plug (A).
- Fill oil of the correct specification through the filling hole (B) until the oil level reach-
es the lower edge of the inspection hole (A).
- Replace the inspection plug (A) and filling plug (B).
Pgear634.bmp
B
C
A
Summary of Contents for Svedala Demag DF 115 P/D
Page 2: ...VALUE QUALITY THE ORIGINAL Your Authorized Dynapac Dealer...
Page 10: ......
Page 18: ......
Page 20: ......
Page 44: ......
Page 60: ...D 1 3 4 D_1 3_01_GB fm 4 24 Element2_konv_Rad_634 bmp 9 12 9a 5 8 14 A 6 7 13 10 11...
Page 62: ...D 1 3 6 D_1 3_01_GB fm 6 24 Element2_konv_Rad_634 bmp 9 12 9a 5 8 14 A 6 7 13 10 11...
Page 80: ...D 1 3 24 D_1 3_01_GB fm 24 24...
Page 120: ...D 4 5 24 D_4 5_01_GB fm 24 34 2 2 Error messages...
Page 121: ...D 4 5 25 D_4 5_01_GB fm 25 34...
Page 122: ...D 4 5 26 D_4 5_01_GB fm 26 34...
Page 123: ...D 4 5 27 D_4 5_01_GB fm 27 34...
Page 124: ...D 4 5 28 D_4 5_01_GB fm 28 34...
Page 125: ...D 4 5 29 D_4 5_01_GB fm 29 34 2 3 FMI codes...
Page 142: ...E 01 12 E_01_GB fm 12 18 3 Auger extension auger type II Auger_DEM bmp...
Page 148: ......
Page 150: ......
Page 153: ...F 3 0 1 F_3 0_01_GB fm 1 4 F 3 0 Maintenance Conveyor 1 Maintenance Conveyor...
Page 157: ...F 4 1 1 F_4 1_01_GB fm 1 8 F 4 1 Maintenance Auger 1 Maintenance auger sub unit...
Page 164: ......
Page 176: ......
Page 177: ...F 6 0 1 F_6 0_01_GB fm 1 8 F 6 0 Maintenance Hydraulic system 1 Maintenance hydraulic system...
Page 190: ......
Page 218: ......
Page 219: ...F 10 0 1 F_10 0_01_GB fm 1 6 F 10 0 Checks decommissioning 1 Tests check up cleaning stopping...
Page 224: ......
Page 232: ......