GMX600 Compact Weather Station
MaxiMet
Applications
Building and Industrial Controls
Authorities
Transport
Coastal
Agricultural
Safety
Educational
Commercial
Energy
WIND SPEED
Range
0.1 m/s to 60 m/s
Accuracy
± 3% to 40 m/s,
± 5% to 60 m/s
Resolution m/s
0.01
Starting Speed
0.1 m/s
Sampling Rate
1 Hz
Units
m/s, km/hr, mph, kts, ft/min
PRECIPITATION
Measurement
type
Optical
Range
0
0 mm/hr
Precipitation
Resolution
0.2 mm
%
Sampling Rate
1 Hz
Units
mm/hr, mm/total, mm/24 hr,
in/hr, in/total, in/24 hr
Heating
YES
WIND DIRECTION
Range
0-359°
Accuracy
± 3° to 40 m/s
± 5° to 60 m/s
Resolution
1°
Sampling Rate
1 Hz
Units
Degrees
TEMPERATURE
Range
-40°C to +70°C
Resolution
0.1
Accuracy
± 0.3°C @ 20°C
Sampling Rate
1 Hz
Units
°C, °F, °K
HUMIDITY
Range
0-100%
Resolution
1%
Accuracy
± 2% @ 20
°
C (10%-90% RH)
Sampling Rate
1 Hz
Units
% Rh, g/m3, g/Kg
DEW POINT
Range
-40°C to +70°C
Resolution
0.1
Accuracy
± 0.3°C @ 20°C
Units
°C, °F, °K
Sampling Rate
1 Hz
ENVIRONMENTAL CONDITIONS
IP Rating
66
Operational
Temperature Range:
-40°C to +70°C
EMC Standard:
BS EN 61326 : 2013
FCC CFR47 parts 15.109
CE Marking
YES
RoHS compliant
YES
Weight
0.8 Kg
Origin
UK
PRESSURE
Range
300 to 1100
Resolution
0.1 hPa
Accuracy
± 0.5 hPa @ 25°C
Sampling Rate
1 Hz
Units
hPa, bar, mmHg, inHg
POWER
Power Supply
5 to 30 Vdc
Power (Nominal)
12 Vdc
mA continuous high
mode. 0. mA eco-power
mode (1 hour polled)
Gill Instruments Limited, Reg No. 2281574
1957-010 Iss
Copyright © Gill Instruments 201
OUTPUTS
Output rate
1/s, 1/min, 1/hr
Digital Comms
Modes
Serial RS232, RS422,
RS485, SDI-12, NMEA,
MODBUS, ASCII
Analogue Outputs Available via separate
optional device
10808 Fallstone Road
Suite 350
Houston, TX 77099
Tel: (281) 564-5100