Now modify the station parameters/ constants in the program to reflect the new settings.
INT_SCAN = 60
INT_STORE = 15
C_ZOM = 5
C_ZOT = 0.004
C_LEV = 2440000
C_HAS = 1002.0
Enter these values in program as shown below.
Save the program as a different name ImetEx2.Cr2. New program is ready for sending to logger for data