Dynamax Inc
24
(For MSX10, MSX20 Setup)
(For MSX5 Setup)
3.2.3 Install InteliMet Advantage 6 Enclosure
InteliMet Advantage 6 weather station enclosure contains CR200 data logger, and other storage or
communication peripherals if any. RF or GSM modem if purchased is assembled inside the enclosure
with surge protector. Sensor cables, Power cables, Communication cables connected to the data logger
or any peripherals routed out of the enclosure through cable glands each marked outside the enclosure
or on the cable itself. So it is not necessary for an end-user to make any wiring inside the enclosure.
All the connectors are accessible out of the box. Position the enclosure on the north side of the mast or
tower (northern hemisphere). Secure enclosure as shown in the figure using U-bolts and mounting
brackets. Route the 12AWG wire from the Ground Lug on the enclosure to the tripod-grounding
clamp. Tighten the screws. Grounding is critical not only for the accuracy of data/ reduces signal noise
but also to protect equipment from any lightening surges.