Intelimet Advantage 6
47
5.3 Monitor Data In Real Time
With communication established between software and the data logger, select
Monitor Values
tab in
PC200 window. This is similar to Numeric panel in PC208 and LoggerNet.
1.
Click on Add button to open the signal list. Select Public from the left column to display public variables
available in the right column. Select desired signals from the right column. Click on a cell in the Monitor
values window, Click Paste button. All the selected signals will be displayed in the Monitor values
window. Note that if you have a long averaging interval, it will take that amount of time to see a new
reading. You may want to temporarily select a smaller interval or use maintenance program to test the
operation. And then download the program with required long term averaging interval later. Any unwanted
signals/ variables in Monitor window can be removed simply by selecting the cell and click
Delete
button.
2.
Once in the Add menu, to select a range of values select the starting label, click on the beginning (for
example TCAir_C) and then a
SHIFT-Click
on the ending of the range (for example RG_mm) and then
click the
Paste
button.
3.
Variable names are self explanatory with units. Any variable name starting with an “i” is an internal
variable or the raw data from the sensor. The same variable name without an “i” is the variable stored in the
logger.
4.
Note any variables displaying a “-NAN” are out of range, or in the case of a sensor input location, it is a
open circuit wire.
5.
In the figure below all Imet sensor variables are displayed in the monitor mode.
List of variable for
monitoring:
Time Stamp
Batt_V
SR_Wpm2
RG_mm
WindSpeed
WindDir
TAmbient
RH
BaroP
Dewpoint
Status
rootTSur_C
ETP_mm