Setting the thread system
Service Instructions 969 - 06.0 - 03/2019
73
8. Turn the blocking cam (10) in the direction of the arrow and switch
on the winder so that the blocking lever (9) rests on the outer diameter
of the blocking cam (10).
The microswitch (11) must not switch off.
A clicking within the microswitch (11) indicates when the
microswitch (11) switches off.
9. Turn the winder shaft until the blocking lever (9) engages in the slot in
the blocking cam (10).
At this position, the microswitch (11) must switch the motor off.
If the microswitch (11) fails to switch off the motor, correct the position
of the microswitch (11).
10. Assemble the thread tension plate together with the winder.
11. Test the winder for correct operation.
Check if the winder (4) switches off when the thread has been wound
up to
0.5 - 1 mm
below the outer diameter of the bobbin (4).
If the winder (4) fails to do so, tighten the screw (2) further or loosen it
and repeat the test.
12. Once the desired result has been obtained, tighten the counternut (3).
Summary of Contents for 969 Classic
Page 1: ...969 Service Instructions...
Page 6: ...Table of Contents 4 Service Instructions 969 06 0 03 2019...
Page 10: ...About these instructions 8 Service Instructions 969 06 0 03 2019...
Page 92: ...Programming 90 Service Instructions 969 06 0 03 2019...
Page 106: ...Decommissioning 104 Service Instructions 969 06 0 03 2019...
Page 108: ...Disposal 106 Service Instructions 969 06 0 03 2019...
Page 119: ...Appendix Service Instructions 969 06 0 03 2019 117 21 Appendix Fig 76 Wiring diagram...
Page 120: ...Appendix 118 Service Instructions 969 06 0 03 2019...
Page 121: ......