3100
AC-RDY timeout, intermediate
circuit voltage did not reach
the defined threshold in the
specified time
• Check mains voltage
• If the mains voltage is OK,
replace the control
3101
High voltage fault, mains
voltage, longer duration
>290 V
• Check mains voltage
• If nominal voltage is
continuously exceeded, stabilize
it or use a generator
3102
Low voltage failure
(2
nd
threshold) (mains voltage
< 150 V AC)
• Check mains voltage
• Stabilize the mains voltage
• Use generator
3103
Low voltage warning
(1
st
threshold) (mains voltage
< 180 V AC)
• Check mains voltage
• Stabilize the mains voltage
• Use generator
3104
Pedal is not in position
0
• When switching the control on,
take your foot off the pedal
3105
U24 V short circuit
• Disconnect 37-pin plug; if error
persists, replace control
• Test inputs/outputs for 24 V
short circuit
3106
U24 V (I
2
T) overload
• One or several magnets
defective
3107
Pedal not connected
• Connect analog pedal
3108
Speed limited due to
insufficient mains voltage
• Check mains voltage
3109
Operation lock
• Check tilt sensor on machine
3150
Maintenance necessary
• Lubricating the needle bar
3151
Maintenance necessary
(operation cannot continue
unless parameter
t 51 14
is
reset)
• Service is required
3155
No release for sewing process • Parameter
t 51 20
-
t 51 33
= 25
3160
Stitch loosening device
• Stitch loosening cannot be
performed
3215
Bobbin stitch counter (info
value 0 reached)
• Change bobbin, set counter
value
3216
Remaining thread monitor left • Change the left bobbin
3217
Remaining thread monitor
right
• Change the right bobbin
3218
Remaining thread monitor left
and right
• Change the left and right bobbin
Code
Possible cause
Remedial action
Summary of Contents for 969 Classic
Page 1: ...969 Service Instructions...
Page 6: ...Table of Contents 4 Service Instructions 969 06 0 03 2019...
Page 10: ...About these instructions 8 Service Instructions 969 06 0 03 2019...
Page 92: ...Programming 90 Service Instructions 969 06 0 03 2019...
Page 106: ...Decommissioning 104 Service Instructions 969 06 0 03 2019...
Page 108: ...Disposal 106 Service Instructions 969 06 0 03 2019...
Page 119: ...Appendix Service Instructions 969 06 0 03 2019 117 21 Appendix Fig 76 Wiring diagram...
Page 120: ...Appendix 118 Service Instructions 969 06 0 03 2019...
Page 121: ......