25
C M F - 5 9 0
O P E R A T I N G I N S T R U C T I O N S
Section 4: Lubrication
The operator should make a check of all grease fittings on the unit before beginning to operate it so as to become
familiar with their location and correct service schedule.
Warning:
Use normal shut-down procedure (Section 3.11) before lubricating the machine.
4.1 Lubrication
Use only a high quality, #2 multi‑purpose grease when lubricating the unit. Make sure all fittings and the nozzle of the
grease applicator are clean before applying the grease. If grease fittings are missing, replace them immediately.
Lubricate with grease every ten (10) hours of operating time.
1. P.T.O. universal joints – 8 places
1a.
As many as seven (8) pumps of grease are required to purge all cross and bearing lube
point with fresh grease.
2. Telescoping shafts – 2 places
2a.
Telescoping members require enough grease to maintain a smooth sliding
action. When telescoping members become contaminated with dirty grease,
they should be inspected and cleaned to insure smooth operation.
2b.
Shield components should be lubed and inspected to insure all components
are in working condition or are replaced if damaged. A properly maintained
shield will inhibit dirt from contaminating telescoping members.
3. P.T.O stand bearing – 1
4. Conveyor bearings - 2
5. Extension conveyor bearings – 2 each
Lubricate with grease every fifty (50) hours of operating time.
6.
Automatic clutches – Two places – 1 pump only.
Be careful not to over grease.
7.
Auger grease line - 1
Summary of Contents for HAYBUSTER CMF-590
Page 2: ...A Tradition of Innovation Since 1966 ...
Page 4: ...A Tradition of Innovation Since 1966 ...
Page 34: ...24 C M F 5 9 0 O P E R A T I N G I N S T R U C T I O N S A Tradition of Innovation Since 1966 ...
Page 49: ...CMF 590 VERTICAL MIXER Part 2 Parts Reference TM 39 ...
Page 50: ...40 C M F 5 9 0 P A R T S R E F E R E N C E R H T U B A S S E M B L Y ...
Page 52: ...42 C M F 5 9 0 P A R T S R E F E R E N C E L H T U B A S S E M B L Y ...
Page 54: ...44 C M F 5 9 0 P A R T S R E F E R E N C E M A I N F R A M E A S S E M B L Y ...
Page 62: ...52 C M F 5 9 0 P A R T S R E F E R E N C E A Tradition of Innovation Since 1966 ...
Page 64: ...54 C M F 5 9 0 P A R T S R E F E R E N C E A U G E R A S S E M B L Y ...
Page 86: ...76 C M F 5 9 0 P A R T S R E F E R E N C E G E A R B O X H Y D R A U L I C S ...
Page 88: ...78 C M F 5 9 0 P A R T S R E F E R E N C E L U B R I C A T I O N T A N K A S S E M B L Y ...
Page 90: ...80 C M F 5 9 0 P A R T S R E F E R E N C E O R B I T M O T O R S 3 9 0 0 0 2 5 3 9 0 0 0 3 2 ...
Page 92: ...82 C M F 5 9 0 P A R T S R E F E R E N C E H Y D R A U L I C C Y L I N D E R A S S E M B L Y ...
Page 96: ...86 C M F 5 9 0 P A R T S R E F E R E N C E 3 1 0 0 2 2 4 P L A N E T A R Y G E A R B O X ...
Page 98: ...88 C M F 5 9 0 P A R T S R E F E R E N C E H U B A S S E M B L Y ...