2-30
12H-M12M0-0309-0
5. INITIALIZING THE MEMORY
If for some reason, the EEPROM (nonvolatile memory) data becomes lost and the display does not function normally,
initialize and recover the data using the following procedure.
Initializing the memory
q
While pressing the start key, stop key, and test key together, turn ON the power. This initializes data except for the
total count registered in the EEPROM of the MC unit. A buzzer sounds three times when the memory is initialized.
w
As the data except for the total count was initialized, reset data such as home position adjustment data of folding
plates and switching shaft in the maintenance mode while checking the backup data form pasted on the inside of
the main cover F.
If data cannot be recovered by the above method, turn ON the power while pressing the start key, stop key,
and clear key together (This initializes all data including the total count). Never perform this method except
when problems have occurred.
Turning ON the power while pressing the test key erases only standard folding adjustment registration and
custom folding registration data.
Note
Note