Spin Welder User’s Manual
Section 6 – Control Functions
Page 39
Page 38
Dukane Manual Part Number 403-547-03
Dukane Manual Part Number 403-547-03
Emergency OFF
The Abort/Emergency OFF switch is located at the
front of the base (see Figure 6–3). When the red
palm switch is pushed in, it will stop the spin welder
regardless of where it is in the cycle. When the
Emergency OFF switch is pushed in, the following
conditions are present:
• The motor and press are disengaged.
• The activation palm buttons are deactivated.
• The air is allowed to bleed out of the downstroke
air cylinder.
• The press may lower if the pneumatic
counterbalance is set too low.
To reset the spin welder, twist the Emergency OFF
switch clockwise and out as shown in Figure 6–4.
Status Display
Directly to the left of the Emergency OFF switch is
the status display. The display is blank when the AC
power is OFF. When AC power is on and the Emer-
gency OFF switch is pushed in, the display indicates
ABORT
in red. When the Emergency switch is out,
the display indicates
POWER
in green. When the
Figure 6–4
Base Status Display and Emergency OFF Switch
ABORT
POWER
IN CYCLE